B915Two-line LCD keypad

Our drawing of the B915 two-line LCD keypad.

Bosch G Series B Series manuals

Start hereB92x Operation ManualUser guide · 2 pages · 631 KBRead it now

Keypad cheat sheet

  • Arm (away)CMD1
    • B915/B920/B921C: use the steps below. B942: touch the green open padlock. B930: use its own guide.
    • Close up first. The ready tick is green; on B915, look for the green house light with the person outside.
    • Press [CMD], then [1] for All On Delay. If asked, enter your passcode and press [ENTER].
    • Leave during the exit beeps; they speed up for the last 10 seconds. If nobody leaves, it switches to Part On.
    • B942 starts arming with a delay; follow any screen prompts and leave before the delay ends.
    Pages 18, 35 and 36, 126, 132, 136, 139 of the Bosch Bx512G Bx512 OperationPage 2 of the B942 B942W Operation Manual enUS 15295003787
  • Arm while homeCMD3
    • For B915, B920 and B921C. On B942, open the nine-square keypad screen first. B930: see its own guide.
    • Part On protects the points set up for this mode. Press [CMD], then [3] for Part On Delay.
    • Enter your passcode and press [ENTER] only if asked. The display shows Part On Delay or Part On Dly.
    • Once Part On starts, entering your passcode and [ENTER] turns it off again.
    • For Part On Instant, use [CMD], [2]. There is no entry delay: opening a protected point starts an alarm.
    Pages 14, 36, 58, 136, 142 and 143 of the Bosch Bx512G Bx512 Operation
  • Disarmyour codeENTER
    • For B915, B920 and B921C, follow the code steps below. B930 has no printed ENTER key: see its own guide.
    • Use your entry door. Enter your passcode, then press [ENTER] within 8 seconds of entering it, before the entry beeps end.
    • This turns off all areas you can control. After a false alarm, also ring your monitoring company.
    • On B942, touch the red closed-padlock picture (yellow for Part On), enter your passcode, then touch [ENTER].
    Pages 17, 35 and 36, 44, 145 of the Bosch Bx512G Bx512 OperationPage 2 of the B942 B942W Operation Manual enUS 15295003787
  • Bypass a zoneCMD0
    • For B915, B920, B921C and B930. On B942, first open the nine-square keypad screen.
    • Bosch calls zones points. A bypassed point cannot detect an intruder or send an alarm report.
    • With the area off, press [CMD], then [0]. Select the point to bypass, then leave with [ESC] (the diagonal arrow on B942).
    • To restore a point, use [CMD], [0], [0] and follow the prompts to select it. Some points return automatically when the area is turned off.
    Pages 36, 38, 52, 66 and 67, 136, 149 and 150 of the Bosch Bx512G Bx512 Operation
  • Alarm memoryCMD871
    • For B915, B920, B921C and B930. On B942, touch the three-dot menu picture, then Events, View Event Memory.
    • On the button keypads, press [CMD], [8], [7], [1] to view event memory.
    • It shows events since memory was cleared. Turning the system on clears this memory.
    • Press [ESC] to leave; on B942, use the diagonal arrow picture.
    Pages 38, 49 and 50, 116, 133 and 134, 200 of the Bosch Bx512G Bx512 Operation
  • Chime on or offCMD6
    • For B915, B920 and B921C. On B942, open the nine-square keypad screen first. B930: see its own guide.
    • Watch Mode chimes once and names a watched point when it opens while the system is off.
    • Press [CMD], then [6]. Enter your passcode and press [ENTER].
    • On B915, B920 or B921C, press [ENTER] again to toggle Watch Mode; [ESC] leaves.
    • On B942, touch Turn On or Turn Off, then leave with the diagonal arrow picture.
    Pages 36, 38, 53, 106, 137, 189 and 190 of the Bosch Bx512G Bx512 Operation
  • Reset smoke detectorsCMD47
    • For B915, B920 and B921C. On B942, open the nine-square keypad screen first. B930: see its own guide.
    • Smoke and shock sensors may need a reset after an alarm. The reset briefly cuts their power.
    • Press [CMD], [4], [7]. Enter your passcode and press [ENTER].
    • Sensors resetting shows for about 3 seconds. If a sensor faults again straight away, check for smoke or fire. Still stuck? Call your security company.
    Pages 36, 52, 71 and 72, 136, 154 and 155 of the Bosch Bx512G Bx512 Operation
  • Change a codeCMD55
    • For B915, B920 and B921C. On B942, open the nine-square keypad screen first. B930: see its own guide.
    • Press [CMD], [5], [5]. Enter your current passcode and press [ENTER].
    • Enter your new passcode, then [ENTER]. Enter it again, then [ENTER]. B915, B920 and B921C show Passcode changed.
    • Use 3 to 6 digits. It cannot match another passcode or be within 2 of it.
    Pages 36, 53, 91 and 92, 137, 174 and 175 of the Bosch Bx512G Bx512 Operation
  • Set the date and timeCMD852
    • For B915, B920 and B921C. B930: see its own guide. On B942, use the three-dot menu, Settings, Date/Time and follow its prompts.
    • On the button keypads above, press [CMD], [8], [5], [2], then [1]. Enter your passcode and press [ENTER].
    • Enter the date in the format shown, then [ENTER]. Change complete shows.
    • Press [2], enter the time, then [ENTER]. For a 12-hour clock, choose AM or PM when asked. Press [ESC] to leave.
    • While typing, [ESC] deletes a wrong digit. Automatic time updates, if enabled, may overwrite your changes.
    Pages 38, 107, 133 and 134, 191 and 192 of the Bosch Bx512G Bx512 Operation
  • Trouble lights
    • B915/B920/B921C: [ENTER] silences a trouble tone. B942: open the nine-square keypad screen, then touch [ENTER]. B930: see its own guide.
    • A trouble tone repeats three tones and a pause. For burglar-point troubles it sounds only if your installer has set that up.
    • SERV or Service messages identify system faults. A communication failure means reports are not getting through: call your security company.
    • B915 has two house lights. The tick, lock and GAS lights below apply to B920/B921C, B930 and B942.
    Yellow caution light onA system, device or point trouble
    Power-plug light flashingNo mains power: running on the battery
    Power-plug light offNo power to the control panel
    Green tick offNot ready to turn on
    Red lock flashingAll areas on, with an alarm going
    Blue GAS flashingGas alarm: leave the building
    B915: house, person insideGreen: ready for Part On. Red: Part On
    B915: house, person outsideGreen: ready for All On. Red: All On
    Pages 20, 27 and 28, 36, 42, 126 and 127, 132 of the Bosch Bx512G Bx512 Operation
  • Send a test signalCMD41
    • For B915, B920 and B921C. On B942, open the nine-square keypad screen first. B930: see its own guide.
    • Press [CMD], [4], [1]. If asked, enter your passcode and press [ENTER]. The panel sends a test report.
    • It checks the link between your alarm and your security company. The shortcut needs panel firmware v3.0x or later.
    • On B915, B920 or B921C you can also use [CMD] [8], then 3, 3, 2, your passcode and [ENTER].
    Pages 36, 52 and 53, 133 and 134, 136 and 137, 160 of the Bosch Bx512G Bx512 OperationPage 1 of the B92x Operation Manual
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

All Bosch G Series B Series manuals

More Bosch G Series models

  • B920 two-line keypad (and red B925F / B926F)

    Panel

    9 manuals

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring

Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.