FBII XL-2-Gold manuals
Start hereXL 2G InstInstallation · 48 pages · 5.6 MBRead it nowKeypad cheat sheet
Arm (away)your codeor#1
- An LED keypad's READY light must be on; an LCD shows SYSTEM: READY. You can't arm with a burglary zone open.
- Key in your 4-digit code. The ARM light comes on and an LCD shows ON: AWAY.
- Leave through your entry/exit door before the exit delay ends.
- If your installer has turned it on, [#][1] quick arms without a code. [#][2] also bypasses zones that aren't ready.
- You always need a code to disarm.
Arm while homeSTAYyour codeorINSTANTSTAYyour code
- Stay arms the outside of the house and leaves the inside zones off, so you can move about.
- When the system is ready, press [STAY], then your code. An LED keypad lights ARM and STAY; an LCD shows ON: STAY.
- If your installer has turned it on, [INSTANT], [STAY], then your code also drops the entry delay: anyone coming in sets it off at once (ON: STAY INSTANT).
Disarmyour code
- Coming in, the keypad sounds to remind you to disarm. An LED keypad also lights the zones you have set off, such as the door.
- Key in your code. The ARM light goes out.
- After an alarm, your code also silences the siren and the keypad.
Bypass a zoneBYPASSyour codezoneorBYPASSzone
- Each detector or door contact is a zone. A bypassed zone is not protected while the system is armed.
- With the system disarmed, press [BYPASS], key in your code, then the zone number (1 to 6).
- A beep confirms it; an LED keypad winks the zone's light slowly. For more zones within 10 seconds, press [BYPASS] and the number.
- If your installer has turned on quick bypass, [BYPASS] and the zone number is enough.
- Fire zones can't be bypassed. Do the same again to unbypass. Bypassed burglary zones normally go back to normal when you disarm.
Alarm memoryyour code
- During an alarm the ARM light blinks fast.
- Afterwards, on an LED keypad, the READY light and the light of each zone that went off blink fast: that's alarm memory.
- Key in your code to clear it. After a fire alarm, [*] clears it too.
Chime on or off#6
- If your installer has set chime on some zones and turned this command on, [#][6] turns chime on or off.
- It switches chime for the whole system. The keypad doesn't show whether it's on, so keep track.
- The chime is a steady 1-second tone from the keypad, and it only sounds while the system is disarmed.
Reset smoke detectorsyour codeor*
- Fire alarm sounding? Key in your code: it silences the bell and the keypad.
- Then clear the alarm memory (an LED keypad's READY light blinks fast): key in your code or press [*]. That resets the smoke detectors for about 8 seconds.
- [*] works for clearing fire alarms only, and is always on.
Panic alarm*+#or7+9or1+3
- Press both keys at the same time: [*]+[#] for Panic, [7]+[9] for Fire, [1]+[3] for Auxiliary.
- Fire and Auxiliary always work, and Fire always sounds. Panic works if your installer has turned it on.
- An XL4600SM keypad also has two keys marked P, top and bottom: press them together.
- Key in your code to reset a sounding panic, fire or auxiliary alarm.
- Forced to disarm? If your installer has set up ambush, user code 6 also sends a silent signal.
Change a codeCODEmaster codeuser numbernew code
- Only the master (user 1) can add or change codes, and only while disarmed. There are 6 users.
- Press [CODE], key in the master code, the user number (1 to 6), then the new 4-digit code.
- A steady tone means it worked. Four short tones mean it didn't: start again from [CODE].
- To delete a user: [CODE], master code, user number (2 to 6), then [*]. User 1 can be changed but not deleted.
- Keep the master code safe: if it's lost, the codes have to be reset in installer mode.
Trouble lights
- On an LED keypad, the zone lights and status lights show the system's state. An LCD keypad shows a message instead.
- A pulsing keypad sounder means a trouble, such as mains loss, a low battery or a fire zone. Your code silences it.
- Your code also clears a communication failure and the alarm memory.
- If no lights are on and the keys don't beep, the keypad needs service.
Pages 17 to 20, 46 of the XL 2G InstZone light blinking fast That zone went into alarm Zone light pulsing slowly A trouble on that zone Zone light winking slowly That zone is bypassed Zone light on steady (LCD: NOT RDY and the zone) That zone is open (faulted) ARM light winking slowly (LCD: COMM. FAILURE) The panel couldn't reach the monitoring station AC/LB light off (LCD: A.C. LOSS) or blinking slowly (LCD: LOW BAT) Off: no mains power, running on the backup battery. Blinking slowly: battery low READY light blinking slowly Installer programming mode READY light blinking fast Alarm memory: key in your code to clear it
All FBII XL-2-Gold manuals
Installer manuals 1
Nothing here matches that.
Try a shorter search, or search every brand.
More FBII models
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.