Chubb AFX manuals
AFx LCD keypad cheat sheet
Arm (away)
- Key in your user ID, then your PIN, as the screen asks. Some systems ask for only one of them.
- The three buttons under the screen have no words on them: each one picks the word shown above it.
- Press the button under On. At All Areas ON?, choose Yes for all, or No, then On for each area, Nxt to move on and Done.
- When Area(s) arming shows, leave by your exit door. Standard delay beeps speed up in the last 15 seconds; other setups use a steady tone.
Pages 10 and 11, 14, 17 and 18 of the Keypad Users Guide R 1-2 Chubb AFxArea(s) to....ON Press the button under OK to confirm; Review goes back so you can change your choice Points not Ok Something is open: press the button under View, then close it or bypass it. Arming then carries on Arm while home
- Stay turns on the doors and windows but leaves the inside motion detectors off, so people can stay in.
- Key in your user ID and PIN, then press the button under Stay.
- If area choices appear, select the areas and confirm with Done and OK. Close or bypass any points the keypad reports as not OK.
- The red keypad light stays on steadily in Stay. It flashes when the system is fully on.
Pages 10 and 11, 17 and 18 of the Keypad Users Guide R 1-2 Chubb AFxStay On Press the button under Stay On, with no Stay Your user isn't allowed to use Stay Disarm
- Come in by your entry door. The keypad beeps and the screen shows To Disarm.
- Key in your user ID and PIN, then press the button under Off. Stay instead keeps the doors and windows armed.
- Finish before entry time ends. Standard beeps speed up in the last 15 seconds; an alternative setup uses a steady tone.
- Forced to disarm? Swap the last two digits of your PIN. This sends a duress alarm unless your installer disabled it.
Pages 11, 14, 18 of the Keypad Users Guide R 1-2 Chubb AFxOff Stay Press the button under Off All Areas Off? Yes: every area. No: set each area with Off, Nxt to move on, then Done Cancel a false alarm
- Log in while the screen shows In Alarm, then answer each screen with the button under your choice.
- Verifying with your PIN tells the monitoring station you are cancelling a false alarm.
- Verify within a minute of the alarm or the station won't accept it. Fire alarms can't be cancelled.
- Cancelling isn't offered everywhere: ask your alarm company if yours does.
Pages 15, 18 of the Keypad Users Guide R 1-2 Chubb AFxSilence System? Press the button under Yes Verify User? Press the button under Yes, then key in your PIN again Off Stay Press the button under Off, then Yes if All Areas Off? shows Had an Alarm, with the sensor's name Press the button under Ack to finish disarming Bypass a zone
- The AFx calls each detector or door contact a point. The area must be off: you can't bypass while it's on.
- Log in, press ► until Menu Options shows Bypass, then press the button under Ok.
- Press the button under Pts for this area's points, or under All for every area. Step through them with ►.
- With the point on screen, press the button under Bypass. Delbyp takes the bypass off again.
- The bypass lifts when the area is next turned off, if your user has that authority. Press ✕ a few times to log out.
Pages 10, 25 of the Keypad Users Guide R 1-2 Chubb AFxPts Next All Pts: this area's points. Next: the next area. All: points in every area Bypass ? Bypass: the system ignores this point. ?: jumps to the next point that isn't OK Chime on or offf+5
- No code needed. Hold the f key (bottom left) and press 5 at the same time.
- Do the same again to turn chime off.
- With chime on, opening a door gives three short, low beeps at the keypad.
- It works while the system is off or in Stay, if your installer has set it up.
Panic alarm◄+►orf+◄or►+✕
- The emergency keys work only if your alarm company supplied them.
- Press the two keys either side of a symbol at the same time. Police: ◄ and ► (the shield).
- Fire: f and ◄ (the flame). Emergency, not medical: ► and ✕ (the star).
- The alarm goes to the monitoring station. It may also sound a siren, depending on how your system is set up.
Change a code
- Log in, press ► until Menu Options shows My Pin, then press the button under Ok.
- Key in your new PIN (4 or 5 digits), then key it in again when asked.
- The last two digits cannot be the same. Avoid consecutive numbers.
- Users, on the same menu, adds or edits other people. It only shows if your user has that authority.
Pages 11, 30 of the Keypad Users Guide R 1-2 Chubb AFxPIN Changed Your new PIN is set; the keypad goes back to its start screen PIN not allowed Choose a different PIN Test the system
- Log in, press ► until Menu Options shows Test, then press the button under Ok. Test only shows for users allowed to test.
- Press the button under System: every siren sounds and every keypad light comes on for 5 seconds. Ignore the ChxSum number.
- For a walk test, press the buttons under Area, Test, then Walk. Open each door and walk past each detector, all within 15 minutes.
- Back at the keypad, press the button under Review to see Pass or Fail for each point tested.
- Tell your monitoring station first if any smoke, fire or panic point will be set off.
Pages 11, 37 and 38 of the Keypad Users Guide R 1-2 Chubb AFxTest? Area System System: the siren and keypad light test. Area: pick an area to walk test Pass or Fail Pass: the point works. Fail: it may have a problem, or it wasn't set off Trouble lights
- The yellow light on means a fault; flashing means the mains power is off.
- A fault may also sound a steady keypad tone, the same as a burglary alarm. Some systems use slow on-off tones.
- To see the fault, log in, press ► until Menu Options shows Status, then the button under Ok. Find System the same way.
- System Fault or Tampered after disarming means a fault happened while armed. Press the button under Ack, then check Status.
- If a fault stays, call your alarm company.
Pages 10, 14, 21, 24, 48 of the Keypad Users Guide R 1-2 Chubb AFxRed light flashing Fully armed (On) Red light on steady Armed in Stay Yellow light on A fault: check Status Yellow light flashing No mains power Power Failure Mains power is off Battery Trouble A backup battery is low, missing or disconnected Phone Trouble or Report Trouble Can't report to the monitoring station System Trouble A tamper, fuse, module or fire circuit fault
Every Chubb AFX manual
User guides 3
Installer manuals 2
Nothing here matches that.
Try a shorter search, or search every brand.
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.