Eagle Alarm Lock manuals
Eagle 4700 cheat sheet
Arm (away)your code
- Check the green READY light is on. If not, a red zone light shows which zone is open.
- Key in your 4-digit arming code. A short beep sounds, READY goes off and the red ARMED light comes on.
- Leave straight away by your usual exit door. If the sounder starts, the exit time is up: quickly key in your code at the keypad, then arm again.
- Four short beeps mean it can't arm, or the code was wrong. Wait at least 3 seconds before keying it in again.
- If your installer has turned on easy arming, P/* then 1 also arms. Disarming still needs a code.
Arm while homeINTERIORyour codeorINTERIORINSTANTyour code
- Eagle calls this perimeter protection: outside doors and windows are armed, and you can move about inside.
- With the READY light on, press INTERIOR, then key in your arming code.
- The ARMED and INTERIOR lights come on with a short beep. The entry delay still applies unless you also select INSTANT.
- For no entry delay too, press INTERIOR and INSTANT (either order) before your code. The INSTANT light comes on as well.
- With INSTANT, the exit delay still runs, but anyone coming back in the entry door sets off the alarm at once. Disarming puts it all back.
Disarmyour code
- Come in by your usual entry door. The sounder runs through the entry delay to remind you.
- Key in your arming code. The red ARMED light goes off and the green READY light comes on, unless a zone is open.
- Sounder pulsing and zone lights flashing as you come in? An alarm happened: leave, and call for help from a neighbour's phone.
- Your code also stops an alarm and silences the bells.
- Forced to disarm? If your installer has set up an ambush code, use it instead: it sends a silent alarm.
Bypass a zoneBYPASSyour codezone
- Zones 1 to 6 are the wired circuits for your doors, windows and other areas. A zone light that's on means that zone is open.
- Press BYPASS, key in your arming code, then the zone number. That zone's light starts flashing.
- More zones within 10 seconds: BYPASS, then the number. After 10 seconds, you need your code again.
- When READY comes on, arm as usual. The same keys undo a bypass, and disarming puts every bypassed zone back.
- If your installer has turned on easy forced arming, P/* then 2 bypasses every open zone and arms.
Reset smoke detectorsyour code
- Key in your 4-digit arming code. It resets the smoke detectors, silences the bells and resets the keypad.
- An open fire circuit shows as a zone light flashing slowly, with the sounder pulsing: a fire trouble.
- Your code silences the sounder. A trouble signal goes to your monitoring centre: get it repaired straight away.
Panic alarmP/*+P/#orF+ForA+A
- Press both P buttons together for police, both F buttons for fire, or both A buttons for another emergency.
- They work 24 hours a day, armed or not.
- Fire always sounds out loud. Police and A (auxiliary) may be silent or loud, as your installer set them.
Change a codeCODEmaster codeuser numbernew code
- Only User 1 (the primary user) can change codes, with the system disarmed. User 5 may be arm-only; an ambush code, if set, is user 6.
- User 1 comes with a factory code: change it straight away. Your installer can tell you if it's still set.
- Press CODE, then User 1's code (a short beep means you're in), then the user number (1 to 8) and the new 4-digit code.
- Check it: arm with the new code, then disarm. A short beep each time means it works. Repeat from CODE for each code.
- To delete a code (not User 1's): CODE, User 1's code, the user number, then P/*. A short beep confirms it.
Trouble lights
- Your arming code silences the keypad sounder. If your installer has turned on easy reset, P/* alone also silences it.
- A fire trouble is also sent to your monitoring centre. Get it repaired straight away.
- It can arm with a bad or disconnected battery, so test the system weekly. Ask your installer how.
Pages 3 to 5, 7 of the Eagle 4700 User ManualREADY light on (green) Everything is closed: ready to arm Zone light on, or flashing after a bypass That zone is open (close or bypass it to arm), or bypassed (the light goes out once armed) Zone light flashing slowly, sounder pulsing Fire trouble: a fire circuit is open AC POWER light off Running on the battery only: check the transformer AC POWER light flashing, sounder pulsing The battery is low Four short beeps It can't arm, or the code was refused Several short beeps Ringback: the monitoring centre confirmed it got a report Steady tone The entry delay is running, or there's an alarm
Every Eagle Alarm Lock manual
User guides 2
Installer manuals 7
Nothing here matches that.
Try a shorter search, or search every brand.
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.