TS0801LCD arming station

Our drawing of the Challenger TS0801 LCD arming station.

Tecom Challenger V8 manuals

Start hereTecom V8User ManualUser guide · 70 pages · 215 KBRead it now

Keypad cheat sheet

  • Arm (away)your codeON
    • For TS0801 and TS0804 LCD keypads. For the TS0006, see its own guide.
    • With Code: showing, enter your PIN then ON on the TS0801, or # (labelled ON) on the TS0804.
    • If areas appear, press 0 then ENTER for all, or an area number then ENTER. Press ENTER when finished; use # on TS0804.
    • The area lights come on. Leave before the exit time runs out.
    • Seven quick beeps with Unsealed mean an input is open. Close or isolate it, press ENTER (# on TS0804), then try again.
    TS0801Your PIN then ON
    TS0804Your PIN then # (ON)
    TS0006See its own guide
    Pages 13 to 15, 19 of the Tecom V8User ManualPage 4 of the Tecom Challenger V8 Quick Reference User Guide
  • Disarmyour codeOFF
    • For TS0801 and TS0804 LCD keypads. For the TS0006, see its own guide.
    • Before entry time ends, enter your PIN then OFF on the TS0801, or * (labelled OFF) on the TS0804.
    • If areas appear, press 0 then ENTER for all, or an area number then ENTER. Press ENTER when finished; use # on TS0804.
    • The area lights go out when disarming succeeds.
    • A flashing area light means an alarm. Follow the disarming steps to reset it; ring your monitoring company if false.
    TS0801Your PIN then OFF
    TS0804Your PIN then * (OFF)
    TS0006See its own guide
    Pages 11, 16 to 18, 25 of the Tecom V8User ManualPage 1 of the Tecom 8-area-LCD-arming station RAS
  • Bypass a zoneMENUyour codeENTER10ENTERzoneENTER
    • For TS0801 and TS0804 LCD keypads. For the TS0006, see its own guide.
    • TS0801: press MENU, your PIN, ENTER. TS0804: press * (MENU), your PIN, # (ENTER). Then enter 10 and press ENTER (# on TS0804).
    • Challenger calls zones inputs. Enter the input number then ENTER (# on TS0804) to isolate it. Repeat for others.
    • Press ENTER to return to the menu, then 0 and ENTER to leave. On TS0804, use # for ENTER.
    • Once fixed, use menu 11 to de-isolate the input. De-isolating an open input may set off an alarm.
    Menu keyTS0801: MENU; TS0804: *
    Enter keyTS0801: ENTER; TS0804: #
    TS0006See its own guide
    Pages 27 and 28, 40 and 41 of the Tecom V8User ManualPage 1 of the Tecom Challenger V8 Quick Reference User Guide
  • Alarm memoryENTERENTER
    • For TS0801/TS0804: ENTER is # and NEXT is * on TS0804. For the TS0006, see its own guide.
    • With There Are No Alarms In This Area showing, press ENTER twice for the quick alarm history.
    • The newest alarm shows first, with its time, date and input.
    • ENTER steps back to older alarms and NEXT forward. Press 1 to scroll the text; 0 exits.
    • During an alarm, ENTER twice lists the inputs in alarm instead.
    Enter keyTS0801: ENTER; TS0804: #
    Next keyTS0801: NEXT; TS0804: *
    TS0006See its own guide
    Pages 24, 26 of the Tecom V8User ManualPage 3 of the Tecom Challenger V8 Quick Reference User Guide
  • Local alarmENTERENTER0ENTER
    • For TS0801 and TS0804 LCD keypads. For the TS0006, see its own guide.
    • A local alarm can occur while the area is in use, such as a fire door opening. The LCD keypad sounds continuously.
    • Press ENTER twice to see the input, then 0 and ENTER to acknowledge it. On TS0804, use # for ENTER.
    • The tone stops. Fix the cause, such as closing the door, or a programmed reminder may sound again.
    TS0801ENTER, ENTER, 0, ENTER
    TS0804#, #, 0, #
    TS0006See its own guide
    Pages 22 and 23 of the Tecom V8User ManualPage 3 of the Tecom Challenger V8 Quick Reference User Guide
  • Set the date and timeMENUyour codeENTER15ENTER
    • For TS0801 and TS0804 LCD keypads. For the TS0006, see its own guide.
    • TS0801: press MENU, your PIN, ENTER. TS0804: press * (MENU), your PIN, # (ENTER). Then enter 15 and press ENTER (# on TS0804).
    • Choose option 2 (Set). Enter Hours, Minutes, Day, Month and Year as two digits each; press ENTER (# on TS0804) after each.
    • Use the 24-hour clock. Complete every prompt; press ENTER to keep an unchanged value. Seconds reset to zero.
    • After Year, the weekday is worked out for you. Press 0 then ENTER (# on TS0804) to leave the menu.
    Menu keyTS0801: MENU; TS0804: *
    Enter keyTS0801: ENTER; TS0804: #
    TS0006See its own guide
    Pages 27 and 28, 52 and 53 of the Tecom V8User ManualPage 1 of the Tecom 8-area-LCD-arming station RAS
  • Test the systemMENUyour codeENTER12ENTERzoneENTER
    • For TS0801 and TS0804 LCD keypads. For the TS0006, see its own guide.
    • TS0801: press MENU, your PIN, ENTER. TS0804: press * (MENU), your PIN, # (ENTER). If authorised, enter 12 then ENTER (# on TS0804).
    • Enter the input number then ENTER (# on TS0804). SEALED or UNSEALED shows its state; OPEN or SHORT means a wiring fault.
    • UNSEALED, OPEN or SHORT gives a steady tone. The tone stops when the input seals.
    • Press ENTER to test another input, ENTER again for the menu, then 0 and ENTER to leave. Use # for ENTER on TS0804.
    Menu keyTS0801: MENU; TS0804: *
    Enter keyTS0801: ENTER; TS0804: #
    TS0006See its own guide
    Pages 27 and 28, 42 of the Tecom V8User ManualPage 1 of the Tecom 8-area-LCD-arming station RAS
  • Trouble lights
    • On TS0801/TS0804, area lights and the LCD show system status; the TS0804 adds TAMPER and fault lights. The TS0006 has neither.
    • For a system alarm, such as Mains Fail or DGP Tamper, press ENTER twice (# on the TS0804) for details.
    • Some reset once fixed. Others need a code allowed to reset them: your code, then OFF (* on the TS0804). Some need a service technician.
    • On an LCD keypad, menu 1 (Panel Status) lists inputs needing attention.
    • A steady tone means a local alarm: see Local alarm. A buzzer with Suppression Ending means a door is still open: close it, or key in your PIN again.
    Area light onThat area is armed
    Area light offThat area is disarmed and in normal use
    Area light flashing slowlyAn alarm happened while the area was in use
    Area light flashing fastAn alarm happened while the area was armed
    TAMPER light flashingAn alarm was caused by tampering
    Comms FailThe panel cannot reach your monitoring centre
    RAS Fail or DGP FailA keypad (RAS) or data gathering panel is off-line
    Battery FailThe backup battery was low when the mains power went off
    Pages 9, 12, 21 and 22, 24 and 25, 29 of the Tecom V8User ManualPage 2 of the Tecom Challenger V8 Quick Reference User Guide
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

All Tecom Challenger V8 manuals

Installer manuals 21

Tecom FAQ2 pages · 156 KBTecom Basic Programming22 pages · 313 KBTecom Complete Programming222 pages · 1.2 MBTecom computer and printer interface2 pages · 212 KBTecom DGP-AC12 pages · 566 KBTecom Ethernet interface24 pages · 313 KBTecom Installation24 pages · 352 KBTecom macro8 pages · 30 KBTecom programming relays6 pages · 22 KBTS0825E Wireless Data Gathering Panel Installation and Programming Guide32 pages · 758 KBTS0867-69 Challenger V8 4-Lift Controller install16 pages · 576 KBVersion 8 Memory expansion IUM2 pages · 107 KBDirect Connect j15 serial1 page · 15 KBIntelligent Access Controller Programming80 pages · 659 KBTecom four door controller basic programming10 pages · 33 KBChallenger Input Wiring NC NO5 pages · 27 KBTecom Challenger Alarm Dialler wiring1 page · 286 KBTS0804 16 Area Keypad datasheet (legacy product)2 pages · 1.7 MB8 Input Expansion Module6 pages · 91 KBMigrating a Challenger V8 panel to Challenger10 -Titan3 pages · 50 KBV8 Numbers1 page · 144 KB

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring