VERSA-LCDMLCD keypad

Satel VERSA manuals
Start hereVERSA Control Panel User ManualUser guide · 46 pages · 1.2 MBRead it nowKeypad cheat sheet
Arm (away)your codethe key with a key on it
- Key in your code, then press ▲ (the key with the key symbol) for full arming. Three short beeps confirm it if keypad sounds are enabled.
- The partition's green LED blinks through the exit delay, then stays on once armed.
- Two partitions? Press 1 or 2, then ▲, your code and # (no code, if your installer allows quick arming).
- Hold ▲ for about 3 seconds, instead of pressing it, to arm with no exit delay: delayed zones then act instantly.
- One long beep: zones are bypassed, or arming was refused. The display says why, if your code is allowed to see it.
Arm while homeyour codethe key with a sun on itoryour codethe key with a moon on it
- VERSA has Day and Night modes: only the zones your installer chose for that mode are armed, so you can stay inside.
- Key in your code, then press ► (the sun key) for Day mode, or ◄ (the moon key) for Night mode.
- If your installer hasn't chosen zones for a mode, that mode isn't available.
- You can change mode without disarming, for example from Night to Full.
Disarmyour codethe key with a cross mark on it
- Come in by your entry route. If enabled, two short beeps every second signal the entry delay.
- Key in your code, then press ▼ (the X key) to disarm and clear an alarm. Three short beeps confirm it if sounds are enabled.
- Two partitions? Press 1 or 2, then ▼, your code, and ▼ or #.
- Keypads with a card reader: bring your card close to the keys and move it away.
- To clear an alarm and stay armed, enter your code and press the key for the mode already armed.
Bypass a zoneyour code*41#then#
- VERSA calls this inhibiting, until the next disarm. Disarm the partition first; your code needs bypass rights.
- Key in your code, press * for the user menu, then 4, 1, #.
- Scroll to the zone with ▼ and ▲. Press any number key to mark it to be inhibited; press again to undo.
- Press # to finish. The marked zones are inhibited.
- 4, 2, # isolates a zone instead: it stays bypassed until you unbypass it.
Alarm memoryyour code*5#
- For the event log, enter your code, *, then 5, #. Scroll with ▲ and ▼.
- A partition’s red LED means an alarm or alarm memory.
- After clearing an alarm: Enter your code and *. Only at 'View cleared zones? 1=Yes', press 1 to see the zones.
- That cleared-zone list lasts until viewed or the system is armed again. Press * to return to the menu, then * to leave.
Chime on or offhold8
- Chime is five short beeps when a door or window opens while the system is disarmed. Your installer picks the zones.
- Hold 8 for about 3 seconds.
- If keypad sounds are enabled: four short beeps and a long one mean chime on; three short beeps mean chime off.
- Your installer decides whether users can switch it.
Panic alarmhold#
- If your installer allows alarms from the keypad, hold # for about 3 seconds for a panic alarm.
- Hold * for about 3 seconds for fire, or 0 for a medical alarm.
- Your installer decides whether the panic alarm is loud or silent.
Change a codeyour code*1#new code#
- Key in your code, press * for the user menu, then 1, #.
- Key in the new code, then press #.
- Three wrong codes may set off an alarm or lock the keypad for 90 seconds.
- If your code has the right, the user menu also adds users (2, 1, #) and removes them (2, 3, #).
Set the date and timeyour code*62#time#date#
- Key in your code, press * for the user menu, then 6, 2, #.
- The current time shows: key in the new time and press #.
- The date shows next: key in the new date and press #.
Trouble lightsyour code*7#
- A blinking yellow LED (the warning triangle) means the system needs your attention, such as a trouble. It's off while armed.
- Key in your code, press *, then 7, #. Scroll with ▼ and ▲. Viewing the troubles stops the trouble beeps.
- Press * to leave. At 'Clear trouble memory? 1=Yes', press 1 to clear it.
- A flashing M in the top corner means that trouble has already ended.
- Have every trouble fixed soon; call your installer if you need help.
Pages 9, 12, 32 of the VERSA Control Panel User ManualPage 49 of the VERSA Programming Manual (10-15)Green LED on Partition armed Green LED blinking Exit delay running Red LED Alarm, or alarm memory, in that partition Yellow LED blinking Trouble or trouble memory: check it Blue LED on Service mode Two short beeps every 3 seconds A new trouble Send a test signalyour code*94#
- Your code needs the Tests right: by default only the administrator's code has it, unless your installer changed that.
- Key in your code, press *, then 9, 4 and # (4. Manual MS tst). A test event code goes to your monitoring station.
- Three long beeps mean it was refused: your code lacks the right, or the function isn't available.
- Phone reporting test: 9, 5, # (station 1) or 9, 6, # (station 2) instead; the screen shows each stage.
Why is my keypad beeping or showing a trouble light?
Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.
All Satel VERSA manuals
User guides 1
Installer manuals 2
Nothing here matches that.
Try a shorter search, or search every brand.
More Satel models
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.