4127Standard fixed-word console

Ademco 4110 / 4120 / 4140 manuals
Start here4140XMPT2 (User)User guide · 54 pages · 1.9 MBRead it nowKeypad cheat sheet
Arm (away)your codeAWAYyour codeAway
- Close doors and windows. NOT READY means something is open: press * (READY) to list the open zones.
- Key in your code, then press AWAY (the 2 key). The keypad beeps twice and the red ARMED light comes on.
- Leave by the entry/exit door before the exit delay ends.
- MAXIMUM (MAX on some keypads: the 4 key) arms the same way with no entry delay: opening any door sets it off at once.
- If your installer has turned on quick arming, press # instead of your code.
Arm while homeyour codeSTAYyour codeStay
- Key in your code, then press STAY (the 3 key). Doors and windows arm; you can move about inside.
- The keypad beeps three times and the red ARMED light comes on.
- Anyone coming in later must disarm within the entry delay.
- INSTANT (the 7 key) is the same with no entry delay: opening the entry door sets it off at once.
Disarmyour codeOFFyour codeOff
- Come in by the entry/exit door. The keypad beeps slowly during the entry delay.
- Key in your code, then press OFF (the 1 key). One beep, and READY shows.
- Press each key within 2 seconds of the last (3 seconds on a 4140XMPT2), or the entry is cancelled.
- Disarming also clears any bypasses.
- If your installer set up duress, the duress code works as normal but can silently alert the monitoring centre.
Bypass a zoneyour codeBYPASS2-digit zoneyour codeBypass2-digit zone
- Each detector or door contact is a zone. Disarm first; fire zones can't be bypassed.
- Key in your code, press BYPASS (the 6 key), then the zone number as 2 digits (05 for zone 5).
- The keypad shows BYPASS and beeps for each zone. Wait for them all, then arm as usual.
- If quick bypass is turned on, code then BYPASS alone bypasses every open zone. On a 4140XMPT2, press # after BYPASS.
- Bypasses clear when you disarm.
Alarm memoryyour codeOFFthenyour codeOFFyour codeOffthenyour codeOff
- If the keypad beeps fast as you come in, an alarm went off. Leave and call the police from somewhere safe.
- When it's safe, key in your code and press OFF. The display shows the zone that went off.
- Fix the cause (close the door or window), then key your code and press OFF again to clear the display.
- Fire alarm: OFF alone silences it, no code needed. Then your code and OFF clear the display.
Chime on or offyour codeCHIMEyour codeChime
- Key in your code, then press CHIME (the 9 key). Chime works only while disarmed.
- Opening a door or window now gives three beeps.
- Do the same again to turn it off.
- A fixed-word keypad shows CHIME while it is on. On a 4140XMPT2, an alpha (text) keypad shows CHIME MODE ON or OFF for about 2 seconds.
Panic alarm1+*or3+#or*+#
- Your installer chooses which keys work and what each sends: silent, audible, personal or fire.
- Press both keys of a pair at the same time. Keypads with A, B and C keys: hold one for 2 seconds.
- On a 4110, 1 and * send a silent alarm and 3 and # an audible one, if programmed. On a 4140XMPT2 your installer sets each pair.
- An audible panic sounds a loud, steady alarm and shows ALARM with a zone number.
Change a codemaster codeCODEuser numbernew codemaster codeCodeuser numbernew code
- Key in the master code, press CODE (the 8 key), then the user number and that person's new 4-digit code.
- 4110: user numbers are 2 to 7, and one beep means done. To delete a code, stop after the user number and wait for one beep.
- 4110 master code: master code, CODE, 1, then the new code twice.
- 4140XMPT2: use a 2-digit user number (01 to 99), then press 0 at the new-user prompt. If changing your own code, enter it again when asked.
- 4140XMPT2 delete: master code, CODE, the user number, the master code again, then 1 to confirm.
Test the systemyour codeTESTyour codeTest
- Disarm and close everything so READY shows, then key in your code and press TEST (the 5 key).
- The keypad beeps every 40 seconds while testing (every 15 seconds on a 4140XMPT2).
- Open each door and window and walk past each detector: 3 beeps each time, and the zone shows.
- The outside siren sounds briefly too: for a second per zone on a 4110, or 3 seconds at the start on a 4140XMPT2.
- No alarms go to the monitoring centre during the test. Key your code and press OFF to finish.
Trouble lights
- CHECK on the display, with beeping, means a trouble. Press any key to stop the beeps.
- Once a problem is fixed, key your code and press OFF to clear the display. On a 4110, do it twice.
Pages 8, 26 to 28 of the user manual ademco 4110Pages 39 and 40 of the 4140XMPT2 (User)CHECK and a zone number A problem with that zone. A fire zone: call for service now BAT (or SYSTEM LO BAT), no zone number The system's own battery is low: call for service BAT (or LO BAT) and a zone number A wireless sensor's battery is low: replace it yourself, or call for service NO AC (or AC LOSS) Mains power is off: running on battery. If only some house lights are out, check your fuses and circuit breakers No display at all (and the POWER light off, on keypads that have one) The system has no power: call for service FC (or COMM. FAILURE) A communication failure: call for service CC (or MODEM COMM) The panel is talking to the monitoring centre dl for over a minute The system is disabled: call for service Send a test signalyour codeTESTyour codeTest
- On a 4110, starting test mode also sends your monitoring company a test report, if your installer has set one up.
- Disarm, then key in your code and press TEST (the 5 key). The outside siren may give a one-second blast.
- The keypad beeps now and then as a reminder. Alarms don't go to the monitoring centre during the test.
- Key your code and press OFF to finish. The 4140 manuals mention no test report, so this is for 4110 panels.
Why is my keypad beeping or showing a trouble light?
Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.
All Ademco 4110 / 4120 / 4140 manuals
User guides 4
Installer manuals 25
Nothing here matches that.
Try a shorter search, or search every brand.
More Ademco models
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.