LED keypad

Our drawing of the Elite / Alert 8-zone LED keypad.

Arrowhead Elite 8 / Alert 8 manuals

Start hereElite 8D OPERATING GUIDEUser guide · 10 pages · 68 KBRead it now

Keypad cheat sheet

  • Arm (away)ARMoryour codeENTERorARMyour codeENTER
    • Open the keypad cover first. Your installer picks one of three ways: [ARM] alone, your code then [ENTER], or [ARM], your code, then [ENTER].
    • The Armed A light comes on, or Armed B, or both, for the areas you armed.
    • Forgot something? If your installer allows it, [ARM] during the exit time disarms again.
    • Keyed a code wrong? Press [ENTER] to clear it and start again.
    Pages 5, 8 of the Elite 8D OPERATING GUIDEPage 8 of the Alert 8 D Install
  • Arm while homeSTAYorSTAYyour codeENTER
    • Open the keypad cover first. Stay mode arms only the zones your installer picked. Some Alert manuals call it Monitor mode.
    • Press [STAY] ([MONITOR] on some keypads), or that key, your code and [ENTER], as your installer set it up.
    • The Armed A (or B) light flashes while stay mode is on.
    • Press [ENTER] straight after arming to arm at once. It also drops the entry delay, so a triggered stay zone alarms straight away.
    Page 6 of the Elite 8D OPERATING GUIDEPages 8, 18 of the Alert 8 D Install
  • Disarmyour codeENTER
    • Open the keypad cover first. Key in your code and press [ENTER]. The Armed lights go out.
    • Stay mode: your code and [ENTER], or [STAY] on its own if your installer allows it.
    • Your code and [ENTER] also reset an alarm and turn the sirens off.
    • If it won't reset, the alarm was in an area your code or this keypad doesn't cover.
    Pages 5 and 6, 8 of the Elite 8D OPERATING GUIDEPage 18 of the Alert 8 D Install
  • Bypass a zoneBYPASSzoneENTER
    • Open the keypad cover first. Each detector or door contact is a zone. Bypass the ones you want left off, before you arm.
    • Press [BYPASS] ([EXCLUDE] on some keypads), then the zone numbers (1 to 8). Each zone's light comes on. Then press [ENTER].
    • On the Alert LED keypad, the Ready/Excl light flashes while a zone is bypassed.
    • Bypasses clear when you disarm. A bypassed 24-hour zone stays bypassed until you take it off.
    • You can only bypass zones in the areas your keypad is set up for.
    Page 7 of the Elite 8D OPERATING GUIDEPages 8, 11 of the Alert 8 D Install
  • Alarm memoryMEMORY
    • Open the keypad cover first. On the LED keypad, the System or Trouble light flashes when there's an event you haven't looked at.
    • Press [MEMORY]. Faults still present show first: the System light with a zone light for each fault.
    • Events then play back, newest first, with a beep between each. The panel keeps the last 127.
    • Press [ENTER] to stop. A Trouble light left on steady means a tamper alarm hasn't reset.
    Pages 5 and 6 of the Elite 8D OPERATING GUIDE
  • Chime on or offCONTROLthenPROGRAM
    • Open the keypad cover first. Chime (day) zones sound the keypad when a detector sees movement. Your installer sets them up and decides if you can switch them off.
    • LED keypad: press [CONTROL], then [PROGRAM]. The Program light flashes while chime is off.
    • Press [CONTROL] then [PROGRAM] again to turn it back on. The Program light goes out.
    • LCD keypad: press [CHIME]. The screen shows CHIME OFF or CHIME ON.
    Page 9 of the Elite 8D OPERATING GUIDEPages 29 and 30 of the Alert 8 D Install
  • Panic alarmPANICor1+3
    • Open the keypad cover first. LED keypad: press [PANIC], or [1] and [3] together. [4] and [6] send fire, [7] and [9] medical.
    • LCD keypad: [CHIME] and [CONTROL] for panic, [A] and [B] for fire, [B] and [CHIME] for medical.
    • On the LED keypad the two-key alarms are off unless your installer turns them on.
    • Your installer also sets whether [PANIC] works at once or needs a 2-second hold.
    • Your code and [ENTER] reset the alarm.
    Page 8 of the Elite 8D OPERATING GUIDEPages 10, 28 and 29 of the Alert 8 D Install
  • Change a codePROGRAMmaster codeENTERthenPROGRAMuser numberENTERnew codeENTER
    • Open the keypad cover first. With the system disarmed, press [PROGRAM] (PROG on an LCD keypad), your master code, then [ENTER]. The Program light comes on.
    • Press [PROGRAM], the user number (1 to 10), then [ENTER]. Any code already there flashes back.
    • Key in the new code (1 to 6 digits) and press [ENTER]. Three short beeps: saved. One long tone: not accepted.
    • To delete a code, press [BYPASS] ([EXCLUDE] on some keypads; LCD keypad: hold [CONTROL], press [0]) instead of a code, then [ENTER].
    • Finish with [PROGRAM] then [ENTER]. On the LED keypad the A light stands for 0 and B for 9.
    Pages 9 and 10 of the Elite 8D OPERATING GUIDEPage 13 of the Alert 8 D Install
  • Set the date and timePROGRAM401ENTERtimeENTER
    • Open the keypad cover first. Get into program mode first: [PROGRAM] (PROG on an LCD keypad), your master code, then [ENTER].
    • For each item, press [PROGRAM], its number from the table, [ENTER], then the value and [ENTER].
    • The time is on the 24-hour clock (1830 is 6:30 pm). The year is two digits.
    • Finish with [PROGRAM] then [ENTER].
    401Time (HHMM)
    403Day: 1 = Sunday to 7 = Saturday
    405Date (1 to 31)
    406Month (1 to 12)
    407Year (2 digits)
    Pages 9 and 10 of the Elite 8D OPERATING GUIDE
  • Trouble lights
    • On the Alert LED keypad, the System or Trouble light flashes when there's a new event to look at.
    • Open the cover and press [MEMORY]. During the fault check, zone lights 1 to 8 mean the faults in the table.
    • The flashing stops once the events have played or you press [ENTER]. System still flashing means that problem hasn't cleared.
    • If your installer left it on, every keypad beeps non-stop when a wireless detector stops checking in, or a zone goes unused too long.
    Ready/Excl on steadyAll zones closed, ready to arm
    Ready/Excl flashingA zone is bypassed
    System flashingNew system alarm
    Trouble flashingNew tamper or trouble alarm (on steady: still active)
    Zone light on / flashingZone open / zone in alarm
    Fault check: light 1, 2, 3, 4Battery low; mains or 12 V fuse; phone line; wireless detector battery low
    Fault check: light 5, 6, 7, 8Remote battery low; wireless detector not reporting; zone inactivity; monitoring call not acknowledged
    Pages 8, 29 and 30 of the Alert 8 D InstallPages 5 and 6 of the Elite 8D OPERATING GUIDE
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

More Arrowhead models

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring

Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.