Icon codepad

Our drawing of the Solution 2000 / 3000 icon codepad.

Bosch EDM Solution 2000 / 3000 manuals

Start hereSol 2000 3000 Users GuideUser guide · 32 pages · 624 KBRead it now

Keypad cheat sheet

  • Arm (away)your code#orhold#
    • Key in your code, then press # (the key marked AWAY).
    • Two beeps, the AWAY icon shows and the exit time starts. The codepad beeps every 2 seconds, then one long beep in the last 10 seconds.
    • Unless your installer has turned it off, holding # until two beeps also arms.
    • A zone still open when the exit time ends is left out until it closes. Opening it after that sets the alarm off.
    • A long beep and no arming means your system won't arm with a zone open: close it or isolate it first.
    Pages 7, 9, 15 of the Sol 2000 3000 Users Guide
  • Arm while homeyour code*orhold*orhold0
    • The panel calls this STAY Mode. The zones your installer chose are left off so you can move about.
    • Key in your code, then press * (the key marked STAY). Unless your installer has turned it off, holding * until two beeps also works.
    • Two beeps and the STAY icon shows. The left-off zones flash during the exit time, then one short beep.
    • STAY Mode 2: hold 0 until two beeps. It leaves off the zones a master code user picked.
    • To pick them: master code, 4, #, then each zone number and *, then # to finish.
    Pages 7, 16 and 17 of the Sol 2000 3000 Users Guide
  • Disarmyour code#
    • Key in your code, then press #. Two beeps tell you it has disarmed.
    • A flashing zone number shows a zone that went into alarm.
    • Under threat, add your duress digit to the end of your code, then press #. It disarms and sends a silent duress alarm, if monitored.
    Pages 17 and 18 of the Sol 2000 3000 Users Guide
  • Bypass a zone**zone*then#
    • The panel calls this isolating. Each detector or door contact is a zone.
    • Press * twice. Three beeps and the STAY icon flashes.
    • Key in the zone number, then *. Its number flashes. Do the same again to undo a zone.
    • Press # when done. Two beeps, and the system is back to disarmed.
    • If your installer has set up code to isolate, start with *, your code, then * instead.
    Pages 19 and 20 of the Sol 2000 3000 Users Guide
  • Alarm memorymaster code8#
    • After you disarm, a flashing zone number shows the zone that went into alarm.
    • To replay the last 256 events, key in your master code, then 8, then #.
    • Three beeps, then the events show one at a time on the codepad, newest first, with a beep each.
    Pages 17, 25 of the Sol 2000 3000 Users Guide
  • Chime on or offhold4
    • The panel calls this day alarm: zones 1 to 4, if your installer set them up, beep the codepad while disarmed.
    • Hold 4 until three beeps to turn it on, or until two beeps to turn it off.
    • While it is on, the STAY icon flashes once every 3 seconds.
    Pages 8, 25 of the Sol 2000 3000 Users Guide
  • Panic alarm1+3or*+#
    • Press 1 and 3 together, or * and # together. A loud panic alarm starts.
    • Press 4 and 6 together for a fire alarm, or 7 and 9 for a medical alarm.
    • Your installer can switch these off or make them silent.
    Pages 18 and 19 of the Sol 2000 3000 Users Guide
  • Change a codemaster code1#user number#new code#
    • Key in your master code, then 1, then #. Three beeps and the STAY and AWAY icons flash.
    • Key in the user number (1 to 32), then #. Two beeps and that number shows.
    • Key in the new code, then #. Two beeps and the icons go out.
    • To delete that user's code instead, press * where you would key in the new code.
    • Only the master code can add or change codes.
    Pages 17 and 18 of the Sol 2000 3000 Users GuidePage 1 of the Sol 2000 & 3000 LCD Icon Codepad
  • Set the date and timemaster code6#datetime#
    • Key in your master code, then 6, then #. Three beeps and the STAY and AWAY icons flash.
    • Key in day, month, year, hour and minute, two digits each, in 24-hour time.
    • Press #. Two beeps and the icons go out. A long beep means a mistake: start again.
    • The panel flags a date and time fault every time it has been powered down. Set it again when that happens.
    Pages 21 and 22 of the Sol 2000 3000 Users Guide
  • Trouble lightshold5
    • A fault makes the FAULTS or MAINS icon flash and the codepad beep once a minute. Press # to stop the beeping.
    • Hold 5 until two beeps. A zone number shows the type of fault (see the table).
    • Hold that same number's key to see more, for example which wireless zone has a low battery.
    • Press # to leave. The FAULTS icon stays on until the fault is fixed.
    1System fault, such as the battery, date and time, phone line or power supply
    2A wireless detector's battery is low
    3A zone's tamper has been set off
    4A detector has seen no movement for the time your installer set
    5A wireless detector has stopped reporting
    6Couldn't report to the monitoring company
    7An output expander or codepad fault
    8A remote's battery is low
    Pages 8, 20 to 22 of the Sol 2000 3000 Users Guide
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

All Bosch EDM Solution 2000 / 3000 manuals

User guides

2
  1. Sol 2000 & 3000 LCD Icon CodepadFiled under Solution 3000 / Sol 2000 3000 UserUser guide2 pp107 KB
  2. Sol 2000 3000 Users GuideFiled under Solution 3000User guide32 pp624 KB

Quick guides

1
  1. Solution 3000 Quick Installation ManualQuick guide58 pp879 KB

Installation manuals

12
  1. 2000 3000 Wiring DiagramFiled under Solution 3000 / Sol 2000 3000 InstallInstallation1 pp38 KB
  2. B426M InstallerFiled under Solution 3000Installation38 pp3.6 MB
  3. B440 Installation ManualFiled under Solution 3000 / Sol 2000 3000 Install / Connetix B440Installation2 pp196 KB
  4. Bosch Cellular RG InstallFiled under Solution 3000 / Sol 2000 3000 InstallInstallation44 pp2.1 MB
  5. IUI-SOL-ICON-2 Keypad Installation ManualInstallation2 pp566 KB
  6. Sol 2000 3000 - Icon Keypad ProgramFiled under Solution 3000 / Sol 2000 3000 InstallInstallation12 pp588 KB
  7. Sol 2000 3000 - Wiring NotesFiled under Solution 3000 / Sol 2000 3000 InstallInstallation4 pp1.1 MB
  8. Sol 2000 3000 InstallFiled under Solution 3000Installation150 pp1.5 MB
  9. Solution 2k 3k Installation ManualFiled under Solution 3000 / Sol 2000 3000 InstallInstallation152 pp1.7 MB
  10. Solution 2000 3000 - Configuration Guide for CSVIP reporting Bosch Security and Safety SystemsFiled under Solution 3000 / Sol 2000 3000 InstallInstallation2 pp124 KB
  11. Solution 2000 3000 Lcd Alphanumeric CodepadFiled under Solution 3000 / Sol 2000 3000 InstallInstallation2 pp168 KB
  12. Tech Update Issue 24 Sol3000 08 2017Filed under Solution 3000 / Sol 2000 3000 InstallInstallation1 pp353 KB

Datasheets

1
  1. B440 product Data sheetFiled under Solution 3000 / Sol 2000 3000 Install / Connetix B440Datasheet4 pp524 KB

Other manuals

2
  1. B450 Communicator specFiled under Solution 3000Manual4 pp630 KB
  2. BOSCH B810 ManualFiled under Solution 3000Manual60 pp1.2 MB

More Bosch EDM models

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring

Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.