Arm (away)your code#
- Close doors and windows, then key in your code and press # (the key marked AWAY).
- Two beeps: the AWAY light comes on. Leave before exit time runs out; one long beep then means it is set.
- A long beep and no arming means a zone is open: close it or isolate it first.
- If your installer allows it, holding # until two beeps also arms the system.
- From the factory, code 0 arms but never disarms. Unless your installer removed it, key in 0, then press #.
Arm while homeyour code*
- Key in your code, then press * (the key marked STAY). The panel calls this STAY Mode 1.
- Two beeps: the STAY light comes on. Zones your installer left off flash until exit time ends with one short beep; the rest is then set.
- For STAY Mode 2, hold 0 until two beeps. It leaves off the zones a master code user picked.
- If your installer allows it, holding * until two beeps also sets STAY Mode 1.
- Unless your installer removed it, the factory code 0 also arms in STAY: key in 0, then press *.
Disarmyour code#
- Key in your code, then press # before the entry time runs out.
- Two beeps tell you the system has disarmed.
- A zone light flashing fast shows the zone that went into alarm while you were out.
- Ultima 880: if there was no alarm, holding * (STAY Mode 1) or 0 (STAY Mode 2) also disarms.
- Under threat, key in your code, then 9, then #. It disarms and, if monitored, sends a silent duress alarm.
Bypass a zone**zone*then#
- Press * twice. Three beeps and the STAY light flashes. The panel calls bypassing isolating.
- Key in the zone number, then *. That zone's light starts flashing slowly.
- Repeat for other zones. To undo one, key in its number and * again.
- Press # to finish. Two beeps: the system is back to disarmed, ready to arm.
- If your installer has set up code to isolate, start with *, your code, then * instead.
Alarm memorymaster code8#
- After you disarm, a zone light flashing fast shows the zone that went into alarm.
- To replay the last 40 events, key in your master code, then 8, then #.
- Three beeps, then the events show one at a time on the lights, newest first, with a beep each.
- On a partitioned Ultima 880, only the last 10 events are replayed.
Chime on or offhold4
- Your installer can set zones 1 to 4 to beep the keypad while disarmed. The panel calls this day alarm.
- Hold 4. Three beeps means day alarm is now on; two beeps means it is now off.
- While it is on, the STAY light flashes once every 3 seconds.
Panic alarm1+3or*+#
- Press 1 and 3 together, or * and # together. The panic alarm sounds.
- Your installer can make it silent or switch it off.
- Press 4 and 6 together for a fire alarm, or 7 and 9 for a medical alarm.
Change a codemaster code1#user number#new code#
- Key in your master code, then 1, then #. Three beeps and the STAY and AWAY lights flash.
- Key in the user number, then #. Two beeps, and a zone light shows which user you picked.
- Key in the new code, then #. Two beeps and the STAY and AWAY lights go out.
- To delete that user's code instead, press * where you would key in the new code.
- Solution 880: keypad codes are users 1 to 8; 9 to 16 are keyfobs. Ultima 880: users 1 to 16.
Set the date and timemaster code6#datetime#
- Key in your master code, then 6, then #. Three beeps and the STAY and AWAY lights flash.
- Key in day, month, year, hour and minute, two digits each, using 24-hour time.
- For example, 5 March 2026 at 2:30 pm is 0503261430.
- Press #. Two beeps and the lights go out. A long beep means the entry was wrong.
Trouble lightshold5
- A new fault flashes the FAULT light and beeps once a minute. Press # once to stop the beeps; FAULT stays on while the fault remains.
- To see which fault it is, hold 5 until two beeps. The zone lights show the fault type (see the table).
- For more detail, hold the number key that matches the zone light showing. Press # to leave.
- The table is for the 880 and 844. On an Ultima 880: 1 system fault, 2 low wireless battery, 3 tamper, 6 failed report.
- Outside the fault check, a zone light on means that zone is open; flashing fast, it went into alarm; flashing slowly, it is isolated.
Pages 7 to 9, 18 and 19 of the 880 userPage 7 of the 880 Ultima UserFAULT light flashing A new fault: press # to stop the beeps MAINS light flashing Mains power is off Fault check: light 1 Low battery Fault check: light 2 The clock was lost: set the date and time again Fault check: light 4 The horn speaker is disconnected Fault check: light 5 The phone line is disconnected Fault check: light 6 or 7 Internal fault or a blown fuse: call your installer straight away Fault check: light 8 The panel couldn't get through to the monitoring company Send a test signalhold9
- Hold 9 until you hear two beeps. The panel sends a test report to your monitoring company.
- The sirens stay quiet. It works only if your system reports by phone.
- On an 844, a report that gets through also clears a communication fault.
Why is my keypad beeping or showing a trouble light?
Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.
All Bosch EDM Solution 840 / 880 manuals
User guides 3
Installer manuals 2
Nothing here matches that.
Try a shorter search, or search every brand.
More Bosch EDM models
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.