Arm (away)your code#
- Close doors and windows, then key in your code and press # (the key marked AWAY).
- Two beeps: the AWAY light comes on and exit time starts. Leave before it runs out.
- One long beep at the end of exit time means the system is set.
- A long beep and no AWAY light means a zone is open: close it or isolate it first.
- If your installer allows it, holding # until two beeps also arms the system.
Arm while homeyour code*
- Key in your code, then press * (the key marked STAY). The panel calls this STAY Mode.
- Two beeps: the STAY light comes on. Zones your installer chose to leave off flash during exit time.
- One short beep when exit time ends: the rest of the system is now set.
- Solution 16, 862 and ICP-CC488 also have STAY Mode 2: hold 0 until two beeps.
- STAY Mode 2 leaves off the zones that a master code user has picked.
Disarmyour code#
- Key in your code, then press # before the entry time runs out.
- Two beeps tell you the system has disarmed.
- On a 6+6 that was set in STAY Mode, key in your code, then * (STAY) instead.
- A zone light flashing fast shows the zone that went into alarm while you were out.
- Under threat, key in your code, then 9, then #. It disarms and, if monitored, sends a silent duress alarm.
Bypass a zone**zone*then#
- Press * twice. Three beeps and the STAY light flashes. The panel calls bypassing isolating.
- Key in the zone number, then *. That zone's light starts flashing slowly.
- Repeat for other zones. To undo one, key in its number and * again.
- Press # to finish. Two beeps: the system is back to disarmed, ready to arm.
- If your installer has set up code to isolate, start with *, your code, then * instead.
Alarm memorymaster code3#ormaster code8#
- After you disarm, a zone light flashing fast shows the zone that went into alarm.
- To replay the last 40 events, key in your master code, then 3, then #.
- On an 862 or ICP-CC488, key in your master code, then 8, then # instead.
- Three beeps, then the events show one at a time on the lights, newest first, with a beep each.
Chime on or offhold4
- Your installer can set zones 1 to 4 to beep the keypad while disarmed. The panel calls this day alarm.
- Hold 4. Three beeps means day alarm is now on; two beeps means it is now off.
- On a Solution 16, 862 or ICP-CC488, the STAY light flashes once every 3 seconds while it is on.
- Solution 16 with v1.10 software: key in your master code, then 7, then # instead.
Panic alarm1+3or*+#
- Press 1 and 3 together, or * and # together. The panic alarm sounds.
- Your installer can make it silent or switch it off.
- Press 4 and 6 together for a fire alarm, or 7 and 9 for a medical alarm.
- Older software (Solution 16 to v1.36, 6+6 to v1.26): 4 and 6, or 7 and 9, give a panic instead.
Change a codemaster code1#user number#new code#
- Key in your master code, then 1, then #. Three beeps and the STAY and AWAY lights flash.
- Key in the user number, then #. Two beeps, and a zone light shows which user you picked.
- Key in the new code, then #. Two beeps and the STAY and AWAY lights go out.
- To delete that user's code instead, press * where you would key in the new code.
- From the factory, user 1 is the master code.
Set the date and timemaster code6#datetime#
- Key in your master code, then 6, then #. Three beeps and the STAY and AWAY lights flash.
- Key in day, month, year, hour and minute, two digits each, using 24-hour time.
- For example, 5 March 2026 at 2:30 pm is 0503261430.
- Press #. Two beeps and the lights go out. A long beep means the entry was wrong.
- Set it again after the power has been off or when daylight saving changes.
Trouble lightshold5
- A new fault makes the FAULT light flash and the keypad beep once a minute.
- Press # once to stop the beeping. The FAULT light then stays on while the fault remains.
- To see which fault it is, hold 5 until two beeps. The zone lights show the fault type.
- Each model has its own fault list, so check your manual. Press # to leave.
Pages 6 and 7, 11 of the Solution 16 UserPages 9, 18 of the 862 user manualFAULT light flashing A new fault: press # to stop the beeps FAULT light on A fault is still there MAINS light flashing Mains power is off Zone light on That zone is unsealed, such as a door left open Zone light flashing fast That zone went into alarm Zone light flashing slowly That zone is isolated
Why is my keypad beeping or showing a trouble light?
Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.
More Bosch EDM models
LCD codepad with prox 'Tag' reader, door closed (CP736B type)
Solution 16+ / 64 / 144
18 manuals
Also fitsSolution 6000, 4 manuals
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.