ITI + Simon SX-IVB manuals

Start hereITI SX-IVB Owner's ManualUser guide · 12 pages · 1.8 MBRead it now

Keypad cheat sheet

  • Arm (away)your code4
    • Arm from a wireless touchpad, with the doors and windows closed.
    • Key in your 4-digit access code, then straight away press 4 (AWAY). Every sensor, inside and out, is armed.
    • Four short beeps from the inside sirens confirm it, and the CPU display shows 4. There is a delay for you to leave.
    • Two-tone protest beeps mean a door or window is open. Its number shows on the CPU with all four red lights: close it, then arm again.
    • Level 5 (SILENT/AWAY) is the same, but the sirens stay quiet for a break-in. Never use it with anyone at home.
    Pages 5 and 6 of the ITI SX-IVB Owner's ManualPages 13 and 14 of the ITI SX-IVB Installation Manual (Jan 1987)
  • Arm while homeyour code3oryour code6
    • For when you're home, use level 3, 6 or 7. Key in your access code, then the level number.
    • 3 (EXTERIOR): the outside doors and windows are armed, with a delay to come and go. Three short beeps.
    • 6 (NIGHT): outside sensors plus some inside ones; bedroom and bathroom sensors are usually left off. Delays apply. One long and one short beep.
    • 7 (INSTANT/NIGHT): the same as 6 with no entry or exit delay, so an opened door alarms at once. One long and two short beeps.
    Pages 5 and 6 of the ITI SX-IVB Owner's Manual
  • Disarmyour code0
    • Key in your access code, then straight away press 0 (CANCEL/DISARM).
    • One long beep means the burglary protection is off. Panic, fire and other 24-hour sensors stay on.
    • The same keys cancel an accidental alarm.
    • Going down a level, say from 4 to 2? Disarm to 0 first, then choose the new level.
    • Under threat? Your duress code then any level works as usual but silently alerts the monitoring station. It can't be cancelled.
    Pages 5 to 7 of the ITI SX-IVB Owner's Manual
  • Bypass a zoneyour codeBYPASS2-digit zone
    • SX-IVB calls zones sensors, each with a 2-digit number. Arm to the level you want first.
    • Then key in your access code, BYPASS and the sensor number. The number shows on the CPU and the BYPASS light comes on.
    • Do one sensor at a time, and before the exit delay ends if you're leaving. A temporary code can't do this.
    • Leaving a window open? Arm as usual, and when the protest beeps start, quickly press BYPASS.
    • Changing the level clears the bypass, so do it again if you still need it.
    Pages 6 and 7, 9 of the ITI SX-IVB Owner's ManualPages 14, 50 of the ITI SX-IVB Installation Manual (Jan 1987)
  • Alarm memorySTATUS
    • Stand where you can see the CPU display and press STATUS.
    • If there was an alarm while it was armed, the ALARM light comes on with the number of each sensor that went off.
    • A blank display means there were no alarms. No beep tells you an alarm happened, so look.
    • The memory clears itself six hours after you disarm. Choosing level 9 (the sensor test) clears it straight away.
    Page 7 of the ITI SX-IVB Owner's ManualPage 13 of the ITI SX-IVB Installation Manual (Jan 1987)
  • Chime on or offyour code2
    • Chime is level 2: a chime sounds whenever an outside door or window opens.
    • Key in your access code, then press 2 (CHIME). Two short beeps confirm it.
    • Any SPECIAL sensors, such as a safe or gun cabinet, stay armed in this level too.
    • To stop the chime, disarm to level 0 with your code and 0.
    Pages 5 and 6 of the ITI SX-IVB Owner's ManualPage 13 of the ITI SX-IVB Installation Manual (Jan 1987)
  • Panic alarmholdPOLICE+POLICEorholdFIRE+FIREorholdAUXILIARY+AUXILIARY
    • On the standard (wood frame) wireless touchpad, press both POLICE, both FIRE or both AUXILIARY buttons together for a full second.
    • The sirens sound and the monitoring station is told.
    • On the small hand-held touchpad, press POLICE and ALARM together for police, or AUXILIARY and ALARM together for 1 second.
    • Panic buttons are armed in levels 0 to 8, so they work even when the system is disarmed.
    Pages 5, 7 of the ITI SX-IVB Owner's Manual
  • Set a temporary codeyour codeSTATUSnew code
    • A second code, say for a babysitter: key in your access code, press STATUS, then the new 4-digit code.
    • The current level's beeps sound if it's accepted. If not, try again.
    • To cancel it, key in your code, press STATUS, then your own code again.
    • The temporary code can't bypass sensors directly.
    • Your installer sets the main access code, in the CPU's program mode. Ask them if it's still the factory code.
    Page 7 of the ITI SX-IVB Owner's ManualPage 82 of the ITI SX-IVB Installation Manual (Jan 1987)
  • Test the systemyour code8oryour code9
    • Test once a week. Level 8 (PHONE TEST) makes a test call to the monitoring station: one long and three short beeps.
    • The call worked when the station sounds your sirens for a few seconds or rings you. The display then goes from 8 to 0.
    • Level 9 (SENSOR TEST) gives one long and four short beeps and scrolls every sensor number. Never use it during a power cut.
    • Trip each sensor, and the touchpad fire (80), police (81) and auxiliary (82) buttons. Each number drops off with a short loud siren beep.
    • Done when no numbers show. Only duress calls work during the test, so after 15 minutes it goes back to level 0 by itself.
    Pages 8 and 9 of the ITI SX-IVB Owner's ManualPage 13 of the ITI SX-IVB Installation Manual (Jan 1987)
  • Trouble lights
    • The CPU (the main unit) shows the protection level, a 2-digit sensor number and four red lights.
    • In a power cut the CPU runs on its battery for up to 15 hours. The display goes blank after about 15 minutes.
    • During a power cut, press STATUS to check it still works: status beeps mean all is well.
    • When the first low battery shows, change all the transmitter batteries in the system. Plan on every 12 to 18 months.
    ALARM light and a numberThat sensor is in alarm
    SUPERVISORY light and a numberThat sensor missed its daily test signal
    LOW BATTERY light and a numberThat sensor's battery is low: replace it now
    BYPASS light and a numberThat sensor is bypassed
    All four red lights, a number and two-tone beepsThat door or window is open, so it won't arm
    Loud steady sirenFire alarm
    Loud on-off sirenIntrusion alarm
    Continuous low beepingAuxiliary (usually medical) or environmental alarm
    Pages 4, 6, 8 and 9 of the ITI SX-IVB Owner's Manual
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

All ITI + Simon SX-IVB manuals

More ITI + Simon models

  • Simon / Simon 2 all-in-one panel

    Simon

    11 manuals

  • 60-820Fixed-display touchpad with door

    Concord

    4 manuals

  • The CareTaker wireless console

    CareTaker

    3 manuals

  • 2000 / 3000All-in-one panel

    Commander

    3 manuals

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring