Magnum Alert RP3000LCD / Gemini LCD keypad

Napco 3000 manuals
Start hereRP3000LCD oi167a userUser guide · 36 pages · 332 KBRead it nowKeypad cheat sheet
Arm (away)your codeON/OFF
- The green STATUS light must be on. If it's off, ZONE FAULTS shows with each open zone: close them first.
- Key in your code, then press [ON/OFF]. The green light goes out and the red ARMED light comes on.
- The window counts down the exit time in 10-second steps. Leave through the exit door before it ends.
- INVALID ENTRY, TRY AGAIN means a wrong code: key it in again straight away.
Arm while homeINTERIORON/OFFyour codeON/OFF
- Your installer may have set one or two groups of inside zones. Press [INTERIOR] until the group you want shows: I1, I2 or I1+I2.
- Press [ON/OFF] to choose it. BYPASS shows on the display.
- Key in your code, then press [ON/OFF]. The red ARMED light comes on and the green light blinks. SYSTEM ARMED shows after the exit time.
- For no entry delay, press [INSTANT] before or after you arm. SYSTEM ARMED I shows and the red light flickers fast.
- With no entry delay, opening the entry door sets off the alarm straight away.
Disarmyour codeON/OFF
- As you come in the keypad sounds, the red ARMED light is on and the window shows ENTRY TIME and DISARM SYSTEM.
- Key in your code straight away, then press [ON/OFF]. The sounder stops and the red light goes out.
- Red light flashing and ALARM on the display? An alarm went off while you were out. If someone may still be inside, leave and call for help from a neighbour's.
- Your code then [ON/OFF] also shuts off an alarm that is sounding.
- Forced to disarm? Key in your 2-digit ambush code, then your code, then [ON/OFF]. It looks like a normal disarm but, if set up, sends a silent alarm.
Bypass a zoneBYPASSzoneorzoneBYPASS
- A bypassed zone isn't protected. Only bypass one you can't fix now, and have it checked soon.
- Press [BYPASS], then the zone number, or the number first and then [BYPASS]. The window shows the zone as BYPASSED.
- Do the same again to put a bypassed zone back.
- If your system needs a code to bypass, key in your code first: BYPASS ENABLED shows, then bypass.
- Bypassed zones go back to normal when the panel is next disarmed.
Alarm memoryyour codeFUNCTIONthenINTERIOR
- After an alarm, ALARM and the zones that went off stay on the display once you disarm. Note them, then press [RESET] to clear it.
- To look back later, key in your code, then press [FUNCTION] until DISPLAY... ALARM LOG shows.
- Press [INTERIOR] (YES). Each alarm shows with its time, area, zone and date.
- Scroll with [INTERIOR] (NEXT) and [INSTANT] (PRIOR). Press [RESET] to go back to normal.
Chime on or offyour codeFUNCTIONthenINTERIOR
- With chime on, the keypad sounds a tone when a chosen zone opens while the system is disarmed.
- Key in your code, then press [FUNCTION] until ACTIVATE... CHIME shows. Press [INTERIOR] (YES).
- A C shows on the display while chime is on.
- To turn it off, do the same and choose DEACTIVATE CHIME. Chime doesn't sound while the system is armed.
Reset smoke detectorsyour codeON/OFFRESETthenRESET
- A fire alarm shows FIRE ALARM and the keypad pulses. If there is a fire, get everyone out and call the fire service from outside.
- No sign of fire? Key in your code and press [ON/OFF] to turn the alarm off. The display then reminds you the fire bell is silenced.
- Press [RESET] to quiet the keypad. Check the smoke detectors: one that went off has its red alarm light on.
- Once the smoke has cleared, press [RESET] again. The keypad resets within about 10 seconds.
Panic alarmF+*orP+*orA+*
- The keys marked F, A and P in blue (also 7, 8 and 9) work with [*], armed or not, if your installer has enabled them.
- Press the key and [*] at the same time.
- F with [*]: fire. P with [*]: police. A with [*]: another emergency.
- Each one alerts your monitoring centre.
Change a codeyour codeFUNCTIONBYPASSthenON/OFF
- Your code must be allowed to program, and only keypad 1 works. Key in your code, then press [FUNCTION].
- Press [BYPASS] until ACTIVATE PROGRAM shows, then [ON/OFF]. Press [INTERIOR] (NEXT) until U01 shows.
- For another user, move the cursor onto the user number with [1] and [2], then change it with [3] and [6].
- Move to the code digits the same way. [3] steps a digit up and [6] down. Use up to 6 digits, with no gaps.
- Press [ON/OFF] (SAVE) to store it. To delete a code, clear each digit with [0], then save. Press [RESET] to leave.
Trouble lightsyour codeFUNCTIONthenINTERIOR
- A system trouble flashes the SYS TBL reminder, pulses the sounder and names the problem on the display.
- Key in your code and press [RESET] to quiet it. If the trouble is still there, SYS TBL stays on.
- To see it again: your code, then [FUNCTION] until DISPLAY... SYS TRBL shows, then [INTERIOR] (YES). [INTERIOR] and [INSTANT] scroll.
- Arming with a trouble gives a 3-second tone and CAN'T ARM SYSTEM. Press [RESET], then arm, and call for service soon.
- Weekly siren test, while disarmed: your code, [FUNCTION] until ACTIVATE... BELL TEST, then [INTERIOR]. It sounds for about 2 seconds; if not, call for service.
Pages 2, 7, 15 and 16, 19, 29 to 31 of the RP3000LCD oi167a userPage 2 of the MA3000 WI658C USERAC POWER LOSS Mains power is off: check the plug-in transformer, the fuse or circuit breaker, and for a power cut LOW BATTERY The backup battery is weak. If it hasn't recharged within 24 hours, it needs replacing FAIL TO COMM The panel couldn't get through to your monitoring centre. A Dialer Test that gets through clears it SENSOR FAILURE A sensor has gone quiet. Clear the message with the RESET... SENSOR MSG function FIRE TROUBLE A fault on the fire zone: press [RESET] to quiet the sounder, then call for service DAY ZONE TRBL A day zone has a problem: press [RESET] to quiet the sounder, then fix the zone CAN'T ARM SYSTEM / ZONES NOT NORMAL A zone is open or faulty. Press [FUNCTION] to see which one, and fix it before arming Send a test signalyour codeFUNCTIONthenINTERIOR
- If your installer has set it up, Dialer Test sends a test to your monitoring centre. It needs a level 3 code, the top user level.
- Key in your code, then press [FUNCTION] until ACTIVATE... DIALER TEST shows. Press [INTERIOR] (YES) to send it.
- Some panels list it as COMM TEST TO CS, in the DIAGNOSTIC menu: select it there with [ON/OFF].
- FAIL TO COMM means it didn't get through. Try again: any report that gets through clears it. [RESET] takes you back.
Why is my keypad beeping or showing a trouble light?
Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.
All Napco 3000 manuals
Installer manuals 3
Nothing here matches that.
Try a shorter search, or search every brand.
More Napco models
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.