RP1016LED keypad

Our drawing of the Magnum Alert RP1016 / RP1054e LED keypad.

Napco 1000e manuals

Start hereRP1000LCD OI139B USERUser guide · 16 pages · 604 KBRead it now

RP1054e LED keypad cheat sheet

  • Arm (away)your code
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. Check the green STATUS light is steady: the burglary zones are ready.
    • Key in your code. The red ARMED/ALARM light comes on and the green light goes off.
    • Leave through your usual exit/entry door before the exit time runs out.
    • Took too long? The keypad sounder warns you. Go back, key in your code to reset, then arm again.
    Pages 5, 8 of the Napco 1000e User
  • Arm while homeBByour code
    • RP1054e LED keypad only; for an LCD keypad, see its own guide.
    • If group bypass is set up, press [B] twice. The yellow BYPASS light comes on. Enter your code to arm; the red ARMED/ALARM light comes on.
    • For no entry delay, hold [4] until it beeps, right before or after arming. Wait 10 seconds after disarming before using hold-[4].
    • With no entry delay, opening the entry door sets off the alarm straight away.
    • Bypasses and entry delay return to normal when you disarm.
    Pages 6, 10 of the Napco 1000e User
  • Disarmyour code
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. Enter through your usual entry door; the keypad sounds.
    • Enter your code. The red ARMED/ALARM light goes off; the green light comes on, flashing if a zone is open.
    • Wrong code? Wait at least 2 seconds before trying again.
    • If the red light is flashing as you walk in, there has been an alarm. Leave, and call the police from a neighbour's phone.
    • Your code also turns off an alarm that is sounding.
    Pages 2, 9 of the Napco 1000e User
  • Bypass a zoneBzoneyour code
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. Only zones set up for bypassing can be left out.
    • Press [B] (the bypass key), then the zone number. The yellow BYPASS light comes on.
    • Hold [2] to see which zones are bypassed.
    • Check the green STATUS light is on, then key in your code to arm.
    • The bypass clears the next time you disarm.
    Pages 5 and 6, 10 of the Napco 1000e User
  • Alarm memoryholdB
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. After an alarm the red light flashes and the zone number stays on display.
    • Write the number down, then hold [9] until it beeps to clear the display.
    • To see the last alarm again later, hold [B] until it beeps and keep holding while it shows each zone.
    • The last alarm stays in the history until a new one, even when you arm again.
    • An alarm on a 24-hour zone shows nothing on the keypad, but it is kept in the history.
    Pages 6, 9 of the Napco 1000e User
  • Chime on or offhold5
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. Chime sounds when a chosen zone opens while disarmed.
    • Hold [5] until the keypad beeps to turn chime on.
    • Hold [5] again until it beeps to turn it off.
    • Wait 10 seconds after disarming before you do this.
    Page 6 of the Napco 1000e User
  • Reset smoke detectorshold9thenyour codethenyour codethenhold9
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. A fire alarm lights FIRE/TROUBLE and pulses the sounder.
    • To reset, hold [9] for 2 seconds, then arm and disarm with your code. Your installer may have set it to stop by itself.
    • The sounder and the FIRE/TROUBLE light stay on. Hold [9] to silence the sounder.
    • The light should go out in about 30 seconds. Still smoke in a detector? Hold [9] every 30 seconds or so until it goes out.
    Page 12 of the Napco 1000e User
  • Panic alarm9+#or*+#orB+#
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. Press both keys together; each pair must be enabled by your installer.
    • Fire: [9] (marked F) with [#]. Police: [*] (marked P) with [#]. Auxiliary: [B] (marked A) with [#].
    • Your installer decides whether it sends a silent alarm to the monitoring centre, sounds the siren, or both.
    • The auxiliary panic usually only reports. The monitoring centre answers with a short ringback beep at the keypad.
    • Forced to disarm? If your installer set up an ambush code, key it in, then your code within 10 seconds. It sends a silent alarm.
    Pages 5, 9 and 10 of the Napco 1000e UserPage 9 of the MA1000e iNSTALLER MANUAL
  • Change a codehold8your codeBuser numbernew codeBB
    • RP1054e LED keypad only; for an LCD keypad, see its own guide.
    • Hold [8] until it beeps, then enter your User Program Code. The first three lights flash and the sounder pulses.
    • Press [B], the user number, then up to 4 digits (1–9 only). MA1000e: users 1–8; MA1008e: users 1–7.
    • To delete a code, press [B] and the user number, with no code after it.
    • Press [B] twice to finish.
    Page 7 of the Napco 1000e UserPages 8 and 9 of the MA1000e iNSTALLER MANUAL
  • Trouble lights
    • RP1054e LED keypad only; for an LCD keypad, see its own guide. A trouble flashes a number and the first three lights.
    • Hold [9] for 2 seconds to stop the trouble beeps. The trouble shows again until it is fixed.
    • Need to arm anyway? Hold [9] until it beeps, then hold [1] to test the siren. If it sounds, arm and get the fault fixed soon.
    • A P on the display with a steady tone means a zone or trouble is stopping you arming. Key in your code again, then fix or bypass the zone.
    1Mains power is off: check for a power cut and that the panel's plug-in transformer is plugged in
    2Low battery: hold [9], then hold [1] to test. Still showing after 24 hours of charging? Call for service
    3Communication failed: disarm, wait 10 seconds, hold [9], then hold [6] to test the phone line. Comes back? Call for service
    4, 5 or 6MA1008e with wireless only: a transmitter has stopped reporting or has a low battery, or the receiver has a fault. Call for service
    7An automatic program download failed: hold [9] to clear it
    8MA1008e (version 2): a fault on the phone line
    Sounder pulsingA day zone has a trouble (hold [3] to see which), or the fire zone has a trouble or an alarm
    Pages 5 and 6, 8 of the Napco 1000e UserPages 9 and 10 of the MA1000e iNSTALLER MANUAL
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

All Napco 1000e manuals

More Napco models

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring

Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.