Radionics D9112 manuals
Start hereD9112B User GuideUser guide · 56 pages · 142 KBRead it nowKeypad cheat sheet
Arm (away)your codeENTorCOMMAND1
- Close doors and windows. Press any number key to list anything still open.
- Key in your passcode and press [ENT]. If enabled, [COMMAND] [1] also arms; enter your code and ENT if prompted.
- ARMING shows, then EXIT NOW with the seconds left, and the keypad beeps. Leave before it runs out.
- Door left open? CHK AREA shows. Press [NEXT] until FORCE ARM shows, then [ENT], if your installer allows force arming.
Arm while homeCOMMAND3orCOMMAND2
- If enabled, perimeter arming protects outside doors and windows while leaving inside detectors off. Close perimeter points first.
- Press [COMMAND] [3], then your code and ENT if prompted. EXIT NOW counts down, then PERIMETR DELAYED shows.
- At bedtime, [COMMAND] then [2] arms the perimeter with no entry or exit delay. The display reads PERIMETR INSTANT.
- With [COMMAND] [2] on, opening an outside door sets the alarm off, so disarm before you go out.
- If partial arming is enabled, leave selected perimeter points open, press [COMMAND] [8], and keep them open until exit time ends.
Disarmyour codeENT
- Come in by your usual entry door. The keypad makes a tweedle tone and shows DISARM NOW.
- Enter your code before entry time ends, then press [ENT] within 8 seconds of finishing the code. The disarmed message returns.
- Alarm sounding? Your passcode and [ENT] silence it. If it was a mistake, ring your alarm company.
- Under threat? If duress is set up, key in your code with its last digit 1 or 2 higher, then [ENT]: it disarms and sends a silent alarm.
Bypass a zoneCOMMAND0zoneENTENT
- Each detector or door contact is a point. A bypassed point is left out of the system. Start disarmed.
- If bypassing is enabled, press [COMMAND] [0]; enter your code and ENT if asked. At ENTER PT NUM, enter the point, then ENT twice.
- Not sure of the number? Press [NEXT] to scroll the list, and [ENT] when the one you want shows.
- PT ## BYPASSED confirms it. NOT BYPASSABLE means that point can't be left out.
- To put it back, press [COMMAND], then [0] twice, and choose the point the same way.
Alarm memoryCOMMAND40
- After an alarm is silenced, ALARM SILENCED keeps scrolling to remind you the details are stored.
- With the system disarmed, press [COMMAND] [4] [0]. Enter your code and ENT if prompted.
- Press [NEXT] to step through: fire alarms first, then alarms, then troubles. NO EVENTS means nothing is stored.
- Press [ESC] to leave. To clear the memory, key in your passcode and press [ESC], or arm the system.
Chime on or offCOMMAND6
- The panel calls this Watch Mode: the keypad chimes once when a watch door or window opens.
- If Watch is enabled, disarm and press [COMMAND] [6]. Enter your code and ENT if prompted. WATCH IS NOW ON shows.
- Press [COMMAND], then [6] again to turn it off. WATCH IS NOW OFF shows.
- Your installer chooses which points chime, and whether Watch Mode comes on by itself when you disarm.
- It won't chime while the keys are lit, which lasts 20 seconds after a key press.
Reset smoke detectorsCOMMAND47
- Fire alarm? Get everyone out and check for smoke or fire. Your passcode and [ENT] silence it.
- Once safe, disarm. If reset is enabled, press [COMMAND] [4] [7], then your code and ENT if prompted.
- SENSORS RESETING shows for about 3 seconds, the display goes blank, then the disarmed message returns.
- Straight back into alarm? Smoke may still be there, or the detector may be faulty. Ring your alarm company.
Change a codeCOMMAND55your codeENTnew codeENTnew codeENT
- If code changes are enabled, press [COMMAND] [5] [5]. At ENTER PASSCODE, enter your current code and [ENT].
- At ENTER NEW CODE, key in a new code of 3 to 6 digits and press [ENT].
- At ENTER NEW AGAIN, key it in once more and press [ENT]. PASSCODE CHANGED confirms it.
- A buzz means that code is taken. A code within 2 of another code is refused, to keep duress codes clear.
- Adding or deleting other people's codes uses [COMMAND] [5] [6] or [COMMAND] [5] [3], if your code has the authority.
Set the date and timeCOMMAND45
- If enabled, press [COMMAND] [4] [5]. Enter your code and ENT if prompted. ENT TIME shows.
- Key in the time on the 12-hour clock and press [ENT].
- At AM ?, press [ENT] for morning. For afternoon, press [NEXT] to show PM ?, then press [ENT].
- At ENT DATE, use the date format confirmed by your alarm company, then [ENT]. Check the displayed time/date; [ESC] finishes.
Trouble lightsCOMMAND4
- A trouble may give three warble tones and a pause, over and over. The display says what is wrong.
- Press [COMMAND] [4] to quiet it; enter your code and ENT if prompted. Your code and [ENT] alone also quiet it and disarm.
- Messages starting with SERVC stay on the display until the fault is fixed (see the table).
- A trouble you've cleared can still be seen in alarm memory: [COMMAND] [4] [0].
Pages 3 and 4, 12 to 14, 29, 47 and 48 of the D9112B User GuideSERVC AC FAIL Mains power to the alarm is off: check its plug-in transformer and circuit breaker SERVC BATT LOW The backup battery is low: call for service if it stays or keeps coming back SERVC BATT MSING The backup battery is disconnected or shorted SERVC COMM FAIL The alarm couldn't get through to your monitoring company: let them know SERVC PH LINE #1 or #2 Phone line trouble: report it to your phone company from another phone SERVC KEYPAD Another keypad has a fault: tell your alarm company CALL FOR SERVICE or SERVC PANEL The panel may not be working: call for service FIRE TROUBLE A fire point has a fault. It clears once the fault is fixed Send a test signalCOMMAND41thenENT
- Ring your security company before you test. It works only if they've allowed it for your passcode.
- At the normal display, press [COMMAND], [4], [1]. If asked, key in your passcode and press [ENT].
- When TEST REPORT? shows, press [ENT]. SENDING REPORT shows, then REPORT SENT for 5 seconds.
- COMM FAIL means it couldn't get through. COMMAND DISABLED or NOT AUTHORIZED: ask your security company.
Why is my keypad beeping or showing a trouble light?
Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.
All Radionics D9112 manuals
Installer manuals 5
Nothing here matches that.
Try a shorter search, or search every brand.
More Radionics models
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.