KPXLCD keypad

Our drawing of the D8x / D16x KPX keypad.

Ness D8x / D16x manuals

Start hereNess Navigator user manualUser guide · 40 pages · 1.5 MBRead it now

Keypad cheat sheet

  • Arm (away)ARMyour codeEorARMEoryour codeE
    • Close doors and windows. Wait until Ready or OK is lit, or the Not Ready light is off.
    • Press ARM (arm on Saturn), your code, then E. Three beeps sound and ARMED shows.
    • Shortcuts, if your installer has turned them on: [ARM] then [E], or your code then [E].
    • Leave before the exit time ends. 3 beeps mark its end.
    • 10 beeps instead of 3: mains off or battery low. A 2-second siren at the end: an open zone was excluded.
    Pages 6, 10 of the D8x-D16x User v5.6Pages 6 and 7, 10, 32 of the Ness-D8xD16x-User Manual rev7-8-1
  • Arm while homeHOMEyour codeEorHOMEE
    • Ness calls this Home mode. The button is HOME on KPX and home on Saturn; older keypads use MONITOR.
    • Only the zones your installer chose, usually doors and windows, are armed. Disarm fully first.
    • Press [HOME], key in your code, then [E]. [HOME] then [E] alone works if your installer allows it.
    • The HOME icon comes on (on an ECO8x, the HOME key lights). Older keypads show MONITOR, or flash ARMED on the LED keypad.
    • Key in your code and [E] to come out of it. This also stops an alarm; re-arm if needed.
    Pages 6 and 7, 12, 32 of the Ness-D8xD16x-User Manual rev7-8-1Pages 7, 12 of the Ness ECO8x User manual
  • Disarmyour codeE
    • Come in through your usual entry door. The keypad beeps as a reminder, if entry beeps are turned on.
    • Key in your code, then press [E] (ENTER on the older LED keypad). ARMED goes off; on an ECO8x the ARM key's light goes out.
    • Made a mistake? Press [E] and start again. Five wrong codes in a row set off the alarm.
    • Your code and [E] also stop an alarm. A flashing strobe light outside means an alarm in the last 72 hours.
    • If your installer turned on duress, 5, 6, 8 or 9 before your code disarms and sends a silent alarm.
    Pages 8, 11, 13, 30 of the D8x-D16x User v5.6Page 11 of the Ness-D8xD16x-User Manual rev7-8-1
  • Bypass a zoneEXCLUDEyour codeEzoneEEorEXCLUDEEzoneEE
    • Use EXCLUDE on KPX or exclude on Saturn. On an ECO8x, the key is marked EXC.
    • Ness calls this Exclude: an excluded zone can't set off the alarm. Press [EXCLUDE], your code, then [E]; the EXCLUDE light comes on.
    • Key in the zone number and press [E]; its light comes on. Repeat for more zones. Doing it again includes the zone.
    • Press [E] to finish. EXCLUDE flashes while any zone is excluded; if it stays steady, you're still in Exclude mode.
    • Excluded zones come back when you next disarm. [EXCLUDE] [E] without a code works only while disarmed, if your installer allows it.
    Pages 15, 30, 32 of the D8x-D16x User v5.6Pages 6, 15, 30 of the Ness-D8xD16x-User Manual rev7-8-1
  • Alarm memoryMEMORYyour codeEorMEMORYE
    • Use MEMORY on KPX or memory on Saturn. On an ECO8x, the key is marked MEM.
    • A flashing MEMORY light means there has been an alarm. Disarm first: memory only opens while disarmed.
    • Press [MEMORY], key in your code, then [E]. [MEMORY] [E] is enough if your installer has turned on the shortcut.
    • Press [MEMORY] once for each event, newest first, up to 30. The lights show what happened (see the table).
    • Press [E] to leave. The MEMORY light stops flashing once you've looked.
    A zone number litThat zone went into alarm
    No lightsThe panel was disarmed
    ARMED or ARM2The panel (or area 2) was armed
    MAINSMains power failed
    BATTERYThe battery was low
    TAMPERTamper alarm, such as the siren cover or panel box
    EXCLUDEPanic alarm. Newer panels also light 1 (panic), 2 (medical) or 3 (fire)
    LINEPhone line failure
    Pages 16 and 17 of the D8x-D16x User v5.6Pages 6, 16 of the Ness-D8xD16x-User Manual rev7-8-1
  • Chime on or off0E
    • A day zone can act as a door chime, like a shop door beeper. With Day mode on, it sounds for 2 seconds.
    • Press [0] then [E] to turn Day mode on or off. While it's on, the HOME icon or light flashes (MONITOR on older LCD keypads).
    • To pick zones: press [P] then [E] (PROGRAM, ENTER on the older LED keypad). Key each zone number and [E], then [E] to save.
    • Your installer sets whether it beeps the keypad, the siren or the strobe, and may have set some day zones for you.
    Pages 6, 18 and 19 of the D8x-D16x User v5.6Pages 7, 17 of the Ness-D8xD16x-User Manual rev7-8-1
  • Panic alarmhold*+#
    • KPX: hold * and # (shield keys) together for at least 1.5 seconds, if your installer enabled it. Saturn: press both keys marked panic.
    • ECO8x: press the flame and cross keys together, if enabled. Older LCD: both * keys; older LED: both PANIC keys.
    • On a KPX or older LCD, * then your code then E also works; * then E needs the panic shortcut enabled. Panic may be loud or silent. Code then E stops sirens.
    • If enabled: fire is 3 then E; medical is 2 then E. XCEL: press 1+3 together for fire, 4+6 for medical. ECO8x: flame then E, cross then E.
    • Medical sends a silent report if monitored and enabled. D8x/D16x panic is unavailable in Program, Memory or Exclude mode; ECO8x specifies Program mode.
    Pages 6, 13 and 14, 32 of the Ness-D8xD16x-User Manual rev7-8-1Pages 2, 4 of the Ness KPX User manual
  • Change a codePmaster codeEP2user numberEnew codeEnew codeEPE
    • These keys are for a D8x or D16x. On an ECO8x, use option 11 to 25 (for codes 1 to 15) in place of 2 and the user number.
    • Disarm first: only the master code (user 1) can do this. Press [P], the master code, then [E]: PROG shows (on an ECO8x, the P key lights red).
    • Press [P], then 2 and the 2-digit user number (01 to 56), then [E]. User 2 is P 2 0 2 E.
    • Key in the new code (3 to 6 digits, not starting with 0) and [E], then the same code again and [E].
    • To delete a code, press [MEMORY] (MEM on an ECO8x) then [E] instead of a new code. Press [P] then [E] to leave program mode.
    Pages 20 to 22, 30 of the D8x-D16x User v5.6Pages 21 and 22 of the Ness-D8xD16x-User Manual rev7-8-1
  • Set the date and timePmaster codeEP341EtimeEPE
    • Clock setting is in the rev 7 and XCEL manuals. The rev 5.6 and ECO8x manuals have no clock.
    • Press [P], key in the master code, then [E].
    • Press [P], a setting number, then [E]: 341 hours, 340 minutes, 342 day, 343 month, 344 year (00 to 63).
    • Key in the new value and press [E]. When you're done, press [P] then [E] to leave.
    • Change the hours when daylight saving starts and ends. An XCEL with a working SIM card sets its own clock.
    Pages 20, 24 of the Ness-D8xD16x-User Manual rev7-8-1Pages 7, 30 of the XCEL User's Manual for KPX+ and Saturn+ LCD Keypads
  • Trouble lights
    • 10 beeps: mains off, a low backup battery, or on newer panels a low wireless battery or phone line fault.
    • Check the plug-pack is plugged in and the power point is switched on. If the battery light keeps flashing, call your installer.
    • Slow non-stop beeps: AutoTime, such as auto-arming, is due. Any key quiets them until the last minute; if your installer allows it, your code without E delays it an hour.
    • Non-stop beeping with the aerial, TAMPER and a zone number flashing is a wireless detector tamper. Any key stops it; call your installer.
    • Siren while disarmed: a 24-hour zone, such as a tamper or panic, went off. Code then [E] stops it; call your installer.
    MAINS flashing (MAINS OFF on a KPX or Saturn)Mains power is off
    BATTERY flashing (LOW BATTERY on a KPX or Saturn)The backup battery is low
    LINE flashingPhone line fault, or the panel couldn't reach the monitoring company
    TAMPER flashingTamper alarm: call your installer
    RADIO flashing (an aerial on a KPX or Saturn)A radio key or wireless device has a low battery
    EXCLUDE flashing (the EXC key on an ECO8x)One or more zones are excluded
    MEMORY flashing (the MEM key on an ECO8x)New alarms in memory: view them to clear the light
    Ready or OK off, or Not Ready onNot ready to arm: a zone is open. Ready or OK also goes off for a power or phone line fault
    Pages 6 and 7, 30 of the D8x-D16x User v5.6Pages 6 and 7, 19, 30 of the Ness-D8xD16x-User Manual rev7-8-1
  • Send a test signalPmaster codeEP66666666EPE
    • Sends a test report to your monitoring company, if your alarm is monitored.
    • Disarm. Press P, the master code, then E: three beeps, and PROG shows.
    • Press P, then 6 eight times, then E. LINE lights while the dialler is on line; on an XCEL, the CELL signal digits flash instead.
    • Press P then E to leave program mode. LINE flashing afterwards means a phone line fault or a failed call.
    Pages 12 and 13 of the D8xD16x installer manual rev7.8.1Page 15 of the D8/D16 XCEL 4G Installation and Programming Manual
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

More Ness models

  • LED keypad

    D8 / D16

    18 manuals

  • PRO-L / PRO-LDKeypad

    Pro series

    6 manuals

  • Touchscreen keypad

    Navigator touchscreen

    4 manuals

  • 5000 series panel keypad

    5000

    3 manuals

  • Keypad

    ECO8x

    3 manuals

  • All-in-one control panel (keypad behind the door)

    R8

    2 manuals

  • SmartLiving (Inim) Joy/GR, Joy/MAX and nCode/G keypads

    Smart Living

    1 manual

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring

Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.