HS2TCHPROBlack touchscreen keypad (BLK)

Our drawing of the PowerSeries Pro HS2TCHPRO (BLK) touchscreen.

DSC PowerSeries Pro manuals

Start herePowerSeries Pro HS3032 / HS3128 / HS3248 User ManualUser guide · 56 pages · 1.6 MBRead it now

Keypad cheat sheet

  • Arm (away)
    • For button keypads (HS2TCHPRO: ask your installer). Close all doors and windows. The Ready light (tick) must be on before you can arm.
    • HS2LCDPRO: hold the empty-house key for 2 seconds. Enter your code or show your tag if asked.
    • Or press [*][0] to quick arm, if your installer has turned it on.
    • The Armed light comes on and the keypad beeps six times, then once a second, faster for the last 10 seconds.
    • When the exit time ends, Ready goes out and the keypad goes quiet. Your code during the exit time cancels arming.
    Pages 9, 14 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User Manual
  • Arm while home
    • For button keypads (HS2TCHPRO: ask your installer). PowerSeries Pro calls this Stay: doors and windows are armed and the inside detectors are bypassed.
    • With Ready on, hold the house-with-person key for 2 seconds. Enter your code if asked, and stay inside.
    • The Armed light comes on and the exit time runs without warning beeps.
    • [*][9], and your code if asked, arms in Stay with no entry delay: opening a door or window sets the alarm off at once.
    • Going to bed? Once in Stay, press [*][1], and your code if asked, for Night mode. Only the zones your installer made Night zones stay off.
    Pages 13, 15 to 17 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User Manual
  • Disarm
    • For button keypads (HS2TCHPRO: ask your installer). Coming in, the keypad sounds. Key in your code, or show your tag, before the entry time runs out.
    • Wrong code? A 2-second error tone sounds. Press [#] and key it in again.
    • Burglar alarm by mistake? Key in your code. Within 30 seconds (or your installer's setting) the alarm report is not sent.
    • Then ring your monitoring company so no one is sent out.
    • Not sure what set it off? Approach the building with care.
    Pages 22, 24 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User Manual
  • Bypass a zone
    • For button keypads (HS2TCHPRO: ask your installer). Each detector or door contact is a zone. A bypassed zone can't set off the alarm.
    • With the system disarmed, press [*][1]. Key in your code if the keypad asks.
    • Key in the zone as 3 digits (005 for zone 5), or scroll to it and press [*]. An LCD shows B. Do it again to undo.
    • [9][9][8] bypasses every open zone, [9][9][9] brings back your last bypasses and [0][0][0] clears them all.
    • Press [#] to go back to Ready. Disarming ends bypasses, except on 24-hour zones. Some zones, such as smoke detectors, may be blocked.
    Pages 9, 18 to 20 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User ManualPage 81 of the PowerSeries Pro English Reference
  • Alarm memory
    • For button keypads (HS2TCHPRO: ask your installer). After an alarm, a light on the keypad comes on. Press [*][3], and your code if asked, to see which zones went off.
    • On an LCD keypad you can also scroll to Alarm Memory and press [*].
    • 'Burglary Verified' means more than one detector was set off; 'Burglary Not Verified' means only one.
    • Disarmed with a remote? Check the alarm memory for anything that happened while you were out.
    Pages 10, 22, 25 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User Manual
  • Chime on or off
    • For button keypads (HS2TCHPRO: ask your installer). Press [*][4], and your code if asked, to turn door chime on or off.
    • Or hold the bell function key, if your installer has enabled it.
    • With chime on, the keypad sounds when an entry/exit door opens.
    Pages 9 and 10, 39 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User Manual
  • Reset smoke detectors
    • For button keypads (HS2TCHPRO: ask your installer). Fire alarm sounding and no fire? Key in your code to silence it, then ring your monitoring company.
    • Hold the circling-arrows function key for 2 seconds if enabled, or press [*][7][2].
    • If the reset works, the alarm is cancelled.
    • If a detector still senses smoke it won't reset, and the alarm comes back. Call your alarm company.
    Pages 9 and 10, 23 and 24 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User Manual
  • Change a code
    • For button keypads (HS2TCHPRO: ask your installer). Press [*][5], then key in the master code (or a supervisor code). The master code is user 01.
    • Key in the user number and press [*][*], or scroll to the user and press [*][*].
    • Key in the new code: 4, 6 or 8 digits, however your installer set it up.
    • A P shows beside the user when it's saved. A code that is already in use gets an error tone.
    • Press [#] to go back to Ready.
    Pages 26 to 28 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User ManualPage 90 of the PowerSeries Pro English Reference
  • Set the date and time
    • For button keypads (HS2TCHPRO: ask your installer). Press [*][6], key in the master code, then [0][1] (or scroll to Time and Date and press [*]).
    • Key in the time as 4 digits on the 24-hour clock: 1430 for 2:30 pm.
    • Then the date as 6 digits, month first (MMDDYY): 28 September 2026 is 092826.
    • Press [#] to go back to Ready. Setting the clock also clears a 'Loss of clock' trouble.
    Pages 10, 31, 41 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User ManualPage 93 of the PowerSeries Pro English Reference
  • Trouble lights
    • For button keypads (HS2TCHPRO: ask your installer). A trouble turns on the Trouble light (triangle) and the keypad beeps twice every 10 seconds. [#] stops the beeps.
    • Press [*][2], and your code if asked. On an LCD, scroll to a trouble and press [*]. Fire trouble beeps stop only once you leave this menu.
    • Outside the [*][2] menu, a flashing Trouble light means the keypad's own batteries are low.
    • If a trouble stops you arming, scroll to Acknowledge All Troubles in the [*][2] menu and press [*].
    • Set a lost clock again. For a low wireless battery, follow that device's instructions; call for service for the rest.
    01 Service requiredSiren circuit, radio jamming, clock or power problem. Set the clock again; call for service for the rest
    02 BatteryThe panel's backup battery, or a power module's, is low or missing
    04 ACMains power is off. The system runs on battery for several hours; no trouble beeps for this one
    05 Device faultA detector, keypad, siren or repeater has a fault
    06 Device batteryA wireless detector, keypad, siren, repeater or remote needs a new battery
    07 Device tamperA device has been opened or tampered with
    11 CommunicationsThe link to the monitoring station (phone line, cellular or internet) has a fault
    03, 08, 09, 10, 12Power, radio, module or network problems: call for service
    Pages 9, 21, 40 to 43 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User ManualPage 82 of the PowerSeries Pro English Reference
  • Send a test signal
    • For button keypads (HS2TCHPRO: ask your installer). Disarm, then press [*][6], the master code, then [0][4].
    • Or after [*][6] and the code, scroll to System Test and press [*].
    • It sends a System Test report to your monitoring company, if your installer has set that up.
    • The sirens, bells and keypad sounders sound and the keypad lights come on for 2 seconds. Press [#] to finish.
    Pages 93, 156, 163 of the PowerSeries Pro English ReferencePages 12, 30 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User Manual
Why is my keypad beeping or showing a trouble light?

Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.

Monitored by Alarm Watch? Call 0800 339 999

All DSC PowerSeries Pro manuals

Is anyone watching your alarm?

An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.

Talk to us about alarm monitoring

Prefer to talk now? Call us on 0800 339 999.

Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring