Start herePowerSeries Pro HS3032 / HS3128 / HS3248 User ManualUser guide · 56 pages · 1.6 MBRead it nowKeypad cheat sheet
Arm (away)*0
- For button keypads (HS2TCHPRO: ask your installer). Close all doors and windows. The Ready light (tick) must be on before you can arm.
- HS2LCDPRO: hold the empty-house key for 2 seconds. Enter your code or show your tag if asked.
- Or press [*][0] to quick arm, if your installer has turned it on.
- The Armed light comes on and the keypad beeps six times, then once a second, faster for the last 10 seconds.
- When the exit time ends, Ready goes out and the keypad goes quiet. Your code during the exit time cancels arming.
Arm while home*9
- For button keypads (HS2TCHPRO: ask your installer). PowerSeries Pro calls this Stay: doors and windows are armed and the inside detectors are bypassed.
- With Ready on, hold the house-with-person key for 2 seconds. Enter your code if asked, and stay inside.
- The Armed light comes on and the exit time runs without warning beeps.
- [*][9], and your code if asked, arms in Stay with no entry delay: opening a door or window sets the alarm off at once.
- Going to bed? Once in Stay, press [*][1], and your code if asked, for Night mode. Only the zones your installer made Night zones stay off.
Disarmyour code
- For button keypads (HS2TCHPRO: ask your installer). Coming in, the keypad sounds. Key in your code, or show your tag, before the entry time runs out.
- Wrong code? A 2-second error tone sounds. Press [#] and key it in again.
- Burglar alarm by mistake? Key in your code. Within 30 seconds (or your installer's setting) the alarm report is not sent.
- Then ring your monitoring company so no one is sent out.
- Not sure what set it off? Approach the building with care.
Bypass a zone*1zone#
- For button keypads (HS2TCHPRO: ask your installer). Each detector or door contact is a zone. A bypassed zone can't set off the alarm.
- With the system disarmed, press [*][1]. Key in your code if the keypad asks.
- Key in the zone as 3 digits (005 for zone 5), or scroll to it and press [*]. An LCD shows B. Do it again to undo.
- [9][9][8] bypasses every open zone, [9][9][9] brings back your last bypasses and [0][0][0] clears them all.
- Press [#] to go back to Ready. Disarming ends bypasses, except on 24-hour zones. Some zones, such as smoke detectors, may be blocked.
Alarm memory*3
- For button keypads (HS2TCHPRO: ask your installer). After an alarm, a light on the keypad comes on. Press [*][3], and your code if asked, to see which zones went off.
- On an LCD keypad you can also scroll to Alarm Memory and press [*].
- 'Burglary Verified' means more than one detector was set off; 'Burglary Not Verified' means only one.
- Disarmed with a remote? Check the alarm memory for anything that happened while you were out.
Chime on or off*4
- For button keypads (HS2TCHPRO: ask your installer). Press [*][4], and your code if asked, to turn door chime on or off.
- Or hold the bell function key, if your installer has enabled it.
- With chime on, the keypad sounds when an entry/exit door opens.
Reset smoke detectors*72
- For button keypads (HS2TCHPRO: ask your installer). Fire alarm sounding and no fire? Key in your code to silence it, then ring your monitoring company.
- Hold the circling-arrows function key for 2 seconds if enabled, or press [*][7][2].
- If the reset works, the alarm is cancelled.
- If a detector still senses smoke it won't reset, and the alarm comes back. Call your alarm company.
Change a code*5master codeuser number**new code#
- For button keypads (HS2TCHPRO: ask your installer). Press [*][5], then key in the master code (or a supervisor code). The master code is user 01.
- Key in the user number and press [*][*], or scroll to the user and press [*][*].
- Key in the new code: 4, 6 or 8 digits, however your installer set it up.
- A P shows beside the user when it's saved. A code that is already in use gets an error tone.
- Press [#] to go back to Ready.
Set the date and time*6master code01timedate#
- For button keypads (HS2TCHPRO: ask your installer). Press [*][6], key in the master code, then [0][1] (or scroll to Time and Date and press [*]).
- Key in the time as 4 digits on the 24-hour clock: 1430 for 2:30 pm.
- Then the date as 6 digits, month first (MMDDYY): 28 September 2026 is 092826.
- Press [#] to go back to Ready. Setting the clock also clears a 'Loss of clock' trouble.
Trouble lights*2
- For button keypads (HS2TCHPRO: ask your installer). A trouble turns on the Trouble light (triangle) and the keypad beeps twice every 10 seconds. [#] stops the beeps.
- Press [*][2], and your code if asked. On an LCD, scroll to a trouble and press [*]. Fire trouble beeps stop only once you leave this menu.
- Outside the [*][2] menu, a flashing Trouble light means the keypad's own batteries are low.
- If a trouble stops you arming, scroll to Acknowledge All Troubles in the [*][2] menu and press [*].
- Set a lost clock again. For a low wireless battery, follow that device's instructions; call for service for the rest.
Pages 9, 21, 40 to 43 of the PowerSeries Pro HS3032 / HS3128 / HS3248 User ManualPage 82 of the PowerSeries Pro English Reference01 Service required Siren circuit, radio jamming, clock or power problem. Set the clock again; call for service for the rest 02 Battery The panel's backup battery, or a power module's, is low or missing 04 AC Mains power is off. The system runs on battery for several hours; no trouble beeps for this one 05 Device fault A detector, keypad, siren or repeater has a fault 06 Device battery A wireless detector, keypad, siren, repeater or remote needs a new battery 07 Device tamper A device has been opened or tampered with 11 Communications The link to the monitoring station (phone line, cellular or internet) has a fault 03, 08, 09, 10, 12 Power, radio, module or network problems: call for service Send a test signal*6master code04
- For button keypads (HS2TCHPRO: ask your installer). Disarm, then press [*][6], the master code, then [0][4].
- Or after [*][6] and the code, scroll to System Test and press [*].
- It sends a System Test report to your monitoring company, if your installer has set that up.
- The sirens, bells and keypad sounders sound and the keypad lights come on for 2 seconds. Press [#] to finish.
Why is my keypad beeping or showing a trouble light?
Most keypads beep or light up a trouble indicator when something needs attention, such as a low backup battery, a power cut or a lost phone or internet connection. Your user guide explains what each light or code means on your model. If it keeps happening, or you are not sure, call your installer or monitoring company.
All DSC PowerSeries Pro manuals
Installer manuals 7
Nothing here matches that.
Try a shorter search, or search every brand.
More DSC models
PowerSeries PC5532Z LED keypad, flap open (PC5516Z keys are the same)
PowerSeries PC5010 / PC5020 / 832
21 manuals
Also fitsPC1565, 4 manuals
- Keypads1 user guide and 4 other manuals5 manuals
- Envoy1 user guide, 1 installation manual and 2 more4 manuals
- Impassa1 user guide and 3 installation manuals4 manuals
- PC10001 user guide and 1 installation manual2 manuals
- PC14041 user guide and 1 installation manual2 manuals
- PC20001 installation manual and 1 manual2 manuals
- WLS9001 user guide and 1 installation manual2 manuals
- SCW9045 / SCW90471 installation manual1 manual
- IP & cellular modules1 quick guide, 4 installation manuals and 9 more14 manuals
Is anyone watching your alarm?
An alarm that only makes a noise relies on someone hearing it. A monitored alarm reports to our A1 graded, NZSA approved control room, watched 24/7 by a team that is New Zealand owned and operated. We can monitor most existing alarms, so you may not need a new one. Thinking about a new alarm or security cameras? Ask us for a quote.
Prefer to talk now? Call us on 0800 339 999.
Home: alarm monitoringBusiness: business monitoringInstaller: bureau monitoring
Manuals are the property of their manufacturers and are provided for reference only; their inclusion here does not imply any endorsement by the manufacturer.